Measurement |
4 Terminal Kelvin/Thomson, eliminating lead resistance errors |
Display |
4.5 digit 15mm 7 segment LED with polarity and overload indication. 2 digit 16 segment LED for unit display |
Ranges |
9 ranges manual selection with up/down keys, automatic selection with autorange function |
Auto Zero |
Permits the automatic zero of amplifiers and external circuits |
Temperature Compensation |
Measurement compensated for the following referenced to 20°C:Copper Cu = 3.93%/KBrass Ms63 = 1.50%/KBrass Ms80 = 1.60%/KAmbient sensed with Pt 100 sensor |
Relay Output |
For the pre-selected upper and lower limit values “Too small”,“Correct”, “Too large” Contact load = 30W max 48V 1 Amp |
Dry Circuit Measurement |
In accordance with DIN 41640 part 4 and IEC – 132-1 Open circuit voltage limited to 18mV |
Interface |
RS232 25 pin D-Bush talk listen function |
Terminals |
4mm safety sockets |
Working Temperature |
0°C to 50°C rel. humidity 90% max. non-condensing |
Storage Temperature |
-20°C to +60°C |
Mains Supply |
230 Volts +6% - 10%45Hz to 65Hz approx. 30VA |
Safety |
IEC 1010 Protective Class 1 |
Dimensions |
255mm x 90mm x 263mm (W D H) approx |
Mass |
5kg approximately
|