| Comet T3418 Specifications |
| Technical Parameters |
Value |
| Output |
RS485 |
| Measured Value |
Temperature + Relative Humidity |
| Construction Type |
Interior |
| Design |
Interior |
| Temperature Measuring Range |
-10 to 50 °C |
| Relay Output |
No |
| Two-State Input |
No |
| Lcd Display |
Yes |
| PoE |
No |
| Relative humidity range |
5 to 95% RH |
| Accuracy of relative humidity measurement |
±2.5% relative humidity from 5 to 60% at 23°C
.±3.0% relative humidity from 60 to 95% at 23°C |
| Accuracy of temperature output |
±0.5°C |
| Available temperature units |
degrees Celsius, Fahrenheit |
| Accuracy and range of dew point temperature output - for more details see graphs |
±1.6°C at ambient temperature T<25°C and RH>30%
range -60 to +80 °C |
| Accuracy and range of absolute humidity output |
±1.5g/m3 at ambient temperature T < 25°C
range 0 to 400 g/m3 |
| Accuracy and range of specific humidity output |
±2g/kg at ambient temperature T < 35°C
range 0 to 550 g/kg |
| Accuracy and range of mixing ratio output |
±2.2g/kg at ambient temperature T < 35°C
range 0 to 995 g/kg |
| Accuracy and range of specific enthalpy output |
±3.5kJ/kg at ambient temperature T < 25°C
range: 0 to 995 kJ/kg |
| Communication protocol |
ModBus RTU and Advantech ADAM compatible protocol |
| Communication speed |
110 to 115200 Bd |
| IP protection |
IP20 |
| Power |
9-30Vdc, current consumption approximately 0.5W |
| Dimensions |
88 x 106 x 33 mm (W x H x D) |
| Material of the case |
ABS |
| Color |
white |
| Weight |
approximately 150g |
| Warranty |
3 years |