Máy đo màu quang phổ 3NH YS6060
Technical Specification
Specification |
YS6060 |
Optical Geometry |
Reflectance: d/8 (SCI⪰ Include UV/Exclude UV)
Transmittance: d/0 (SCI⪰ Include UV/Exclude UV)
Conforms to CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 |
Specular Component |
Reflectance: SCI&SCE
Transmittance: SCI&SCE |
Integrating Sphere Size |
Φ 154mm |
Sensor |
256 Image Element Double Array CMOS Image Sensor |
Light Source Device |
360nm-780nm Combined LED Lamp, 400nm cut-off, 420nm cut-off, UV Lamp |
Illuminants |
D65, A, C, UV, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12 |
Spectrophotometric Mode |
Concave Grating |
Observer Angle |
2° & 10° |
Repeatability |
Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.04% (400 nm to 700 nm: within 0.04%)
Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.01 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration)
Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%)
Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.02 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) |
Inter-instrument Error |
Φ25.4mm/SCI, Within ΔE*ab 0.15
(Average for 12 BCRA Series II color tiles) |
Wavelength Range |
360-780nm |
Wavelength Pitch |
10nm |
Semiband Width |
10nm |
Reflectance Range |
0~200% |
Measuring Aperture |
Reflective: Φ30mm/Φ25.4mm, Φ18mm/Φ15mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm;
Transmissive: Φ30mm/Φ25.4mm; |
Color Space |
CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter LAB, Munsell, s-RGB, HunterLab, DIN, βxy |
Color Difference Formula |
ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00v, ΔE(Hunter), DIN ΔE99 |
|