Measuring Principle |
Hydrostatic |
Characteristic |
Smart and reliable pressure transmitter with capacitive measuring cell and ceramic process isolating diaphragm Ceraphire) |
Supply / Communication |
4 ..20mA HART:
11,5...45V DC
Ex ia: 11,5...30V DC
PROFIBUS PA/ FOUNDATION Fieldbus:
9..32 V DC (Non Ex)
|
Accuracy |
Standard 0,15%
Platinum 0,075% |
Long term stability |
0,1% of URL/year |
Process temperature |
-40°C...130°C
(-40°F...266°F
150°C for 1h
(302°F for 1h)
|
Ambient temperature |
-40°C...85°C
(-40°F...185°F) |
Measuring range |
100mbar...40bar
(1.5psi...600psi) |
Max. overpressure limit |
60bar (900psi) |
Process connection |
Thread:
G1/2...G2, R1/2, MNPT1/2
Flange:
DN25...DN80,
ASME 1"...4",
JIS 10K |
Hygienic |
Tri-Clamp
DIN11851
DIN11864-1
NEUMO
Varivent N
SMS
DRD |
Output |
4...20 mA
4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus |
Certificates / Approvals |
ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI
SIL
EN10204-3.1
NACE
CoC ASME-BPE
3A, EHEDG
Marine |
Options |
Display
PWIS free |
|