Active Power
Function |
Range |
Accuracy |
ACW / DCW |
0.000kW – 599.9kW |
A, error*V, reading + V, error *A, reading |
Voltage
Function |
Range |
Accuracy |
DCV |
0.00 – 999.9V |
± (0.7% + 2dgt) |
ACV |
0.00 – 999.9V |
± (1.0% + 5dgt) |
LPF (ACV) |
0.00 – 999.9V |
± (1% + 5dgt) @ 50Hz - 500Hz
± (5% + 5dgt) @ >60Hz - 400Hz |
Resolution (all) |
0.01 V |
|
Current
Function |
Range |
Accuracy |
DCA |
0.00A – 99.99A 100.0A - 599.9A |
± (1.5% + 0.2 A)
± (1.5% + 5dgt) |
ACA |
0.10A – 599.9A |
± (1.5% + 5dgt) 50Hz - 60 Hz
± (2% + 5dgt) >60Hz - 500 Hz |
LPF |
0.10A – 599.9A |
± (1.5% + 5dgt) 50Hz - 60 Hz |
ACA |
|
± (5% + 5dgt) >60Hz - 500 Hz |
Peak Hold: Peak Max / Peak Min
Function |
Range |
Accuracy |
ACV |
140.0V 140.0V |
± (3.0 % + 15dgt) |
ACA |
140.0A 850A |
± (3.0% + 15dgt) |
Frequency
Function |
Range |
Accuracy |
Frequency |
20.00Hz - 9.999kHz |
± (0.5% + 3dgt) |
Total Harmonic Distortion
Function |
Range |
Accuracy |
ACA /ACV |
0.1 – 99.9% |
± (3.0% + 10dgt) |
Resolution |
0.1% |
|
|
|
|
Harmonic Order |
Range |
Accuracy |
H01 ~ H12 |
0.1 – 99.9% |
± (5% + 10dgt) |
H13 ~ H25 |
0.1 – 99.9% |
± (10% + 10dgt) |
Resolution |
0.1% |
|
Inrush Current
Function |
Range |
Accuracy |
ACA |
0.00A - 99.99A
100.0A - 599.9A |
± (2.5 % + 0.2A)
± (2.5 % + 5dgt) |
Power Factor
Range |
-1.00 - 1.00 |
Resolution |
0.01 |
Basic Accuracy |
± 3°± 1dgt |
Resistance, Continuity & Diode
Function |
Range |
Accuracy |
Resistance |
0.0Ω - 999.9Ω
1.000 kΩ -99.99 kΩ |
± (1.0% + 5dgt)
± (1.0% + 3dgt) |
Continuity |
0.0Ω - 999.9Ω |
± (1.0% + 5dgt) |
Diode |
0.40 ~ 0.80V |
± 0.1V |
Capacitance
Function |
Range |
Accuracy |
Capacitance |
0.000 μF - 4000 μF |
± (1.9% + 8dgt) |
Resolution |
0.001 μF max |
|
General
Safety |
IEC 61010 |
Power Requirement |
Single 9V battery |
Battery life |
~ 100 hours (alkaline battery) |
Size |
87 mm (W) x 239 mm (L) x 51 mm (H) |
|