H7331 Temperature, Humidity, Pressure Regulator with Two Relay and RS232 Outputs
Humidistat is designed for two-state control of e.g. heating, ventilation, humidifier, dehumidifier, etc
Transmitter is equipped with two relay outputs for alarm indication or control of external devices
Parameters are easy adjustable from regulator keyboard or from the computer
Large dual line LCD for simultaneous display of temperature
State-of-the-art capacitive polymer sensor ensures excellent calibration long term stability

Liên Hệ Hỗ Trợ

    • SĐT: 0984 843 683

    • Mail: info@ttech.vn

      • Zalo: 0984.843.683

Thông tin sản phẩm

Comet H7331 Specification
Technical Parameters Value
Output RS232
Measured Value Temperature + Relative Humidity + Atmospheric Pressure
Construction Type With T+RH Probe on Cable
Design Industrial
Temperature Measuring Range -30 to 105 °C
Relay Output Yes
Two-State Input Yes
Lcd Display Yes
PoE No
Maximum switching voltage, current, power of relay output 50V, 2A, 60VA
Audible alarm from built-in beeper - switchable
Relative humidity range 0 to 100%
Accuracy of relative humidity measurement ±2.5% relative humidity from 5 to 95% at 23°C
Accuracy of temperature output ±0.4°C from -30 to +100°C ±0.4% from reading over +100°C
Available temperature units degrees Celsius, Fahrenheit
Accuracy and range of dew point temperature output - for more details see graphs ±1.5°C at ambient temperature T<25°C and RH>30% range -60 to +80 °C
Accuracy and range of absolute humidity output ±1.5g/m3 at ambient temperature T < 25°C range 0 to 400 g/m3
Accuracy and range of specific humidity output ±2g/kg at ambient temperature T < 35°C range 0 to 550 g/kg
Accuracy and range of mixing ratio output ±2g/kg at ambient temperature T < 35°C range 0 to 995 g/kg
Accuracy and range of specific enthalpy output ±3kJ/kg at ambient temperature T < 25°C range: 0 to 995 kJ/kg
Maximum measuring pressure range 600 to 1100hPa
Accuracy ±(1,3hPa+0.06% from adjusted output span) at 23°C from 800 to 1100hPa
Available pressure units hPa, kPa, mbar, mmHg, inHg, inH2O, PSI, oz/in2
Signal for binary inputs dry contact, open collector or two-state voltage signal. Inputs are not galvanically isolated.
Minimum pulse length at binary input 500 ms
Voltage at open contact 3.3 V
Low voltage level 0 to +0.5 V
High voltage level +3.0 to +30V
Temperature operating range -30 to +80°C
Temperature operating range of LCD display readable to operating temperature +70°C, it is recommended to switch OFF the LCD over +70°C
Temperature compensation of the humidity sensor all temperature range
Filtering ability of sensor cover 0.025mm - filter with stainless steel mesh
Communication protocol ModBus RTU and Advantech ADAM compatible protocol
Communication speed 110 to 115200 Bd
IP protection IP54 electronics, IP40 sensors
Power 9-30Vdc, power consumption approximately 1W
Length of the probe cable 1m, 2m or 4m optionally
Dimensions 136 x 159 x 45 mm (W x H x D), probe length 88 mm, probe diameter 18mm
Weight approximately 500g