Thiết bị kiểm tra an toàn điện Ainuo AN1637H(F), AN1638H(F)

Liên Hệ Hỗ Trợ

    • SĐT: 0984 843 683

    • Mail: info@ttech.vn

      • Zalo: 0984.843.683

Thông tin sản phẩm

Thiết bị kiểm tra an toàn điện Ainuo AN1637H(F), AN1638H(F)


Function expansion & type

Model Function
AN1637H(F) 200VA capacity, ACW/DCW/IR/GB
AN1638H(F) 500VA capacity, ACW/DCW/IR/GB


Specification

AC withstand voltage test
Rated output capacity 200VA (5000V/40mA), short circuit current is greater than 200mA;
(Optional: 500VA (5000V/100mA), short-circuit current greater than 200mA;)
Output voltage Range/accuracy 100~5000V, ±(1%× setting +5V)
Output frequency Range/accuracy 50Hz or 60Hz, ±0.1%× setting
Alarm current Upper limit/accuracy 0.10~40.00mA, ±(1%× setting +5 words)
Lower limit /accuracy 0.000~9.999mA, ±(1%× setting +5 words)
Time Range 0.5~999.9s (0: infinite time)
Ramp-up time 0, 0.1~999.9s (0: off)
Ramp-down time 0, 0.1~999.9s (0: off)
Accuracy ± (0.2%× setting +1 word)
Measure meter Voltage range/accuracy 0.01~5.00kV, ± (1%× reading +2 words)
Current range/accuracy 0.10~40.00mA, ± (1%× reading +5 words)
Time range/accuracy 0.1~999.9s, ± (0.2%× reading +1 word)
Output voltage wave, distortion, adjusting rate Sine wave, less than 2% (pure resistive load), ±(1% × setting + 5V) (from zero to full load)
Start voltage (0%~50%)× output voltage setting
Current compensation 0.000~40.00mA, Auto/manual
Arc detection Level 1~9, 9: highest level; 0: off
DC withstand voltage test
Output voltage Range/accuracy 100~6000Vdc, ± (1%× setting +5V)
Alarm current Upper limit/accuracy 0~10000μA, ± (1%× setting +5 words)
Lower limit /accuracy 0.0~999.9μA, ± (1%× setting +5 words)
Time Range 0.5~999.9s(0: infinite time)
Ramp-up time 0,0.4~999.9s(0为关闭)
0, 0.4~999.9s (0: off)
Ramp-down time 0, 1.0~999.9s (0: off)
Accuracy ± (0.2%× setting +1 word)
Measure meter Voltage range/accuracy 0.01~6.00Vdc, ± (1%× reading +1 words)
Current range/accuracy 0.0~10000uA, ± (1%× reading +1 words)
Time range/accuracy 0.1~999.9s, ± (0.2%× reading +1 word)
Rated output capacity 60VA(6000Vdc/10mA)
Output voltage ripple, adjustment ± (1%× setting +2V), zero to full load
Compensation current 0 ~200.0μA, Auto/manual
Start voltage (0%~50%)×output voltage setting
Charging current lower limit (0~3.500) μA, Auto/manual
Discharge time ≤200ms
Arc detection Level 1~9, 9: highest level; 0: off
Insulation resistance test
Output voltage Range/accuracy 100~2500Vdc, ± (1%× setting +5V)
Alarm resistance Upper/lower limit 0.1MΩ~999.99MΩ, 1000MΩ~50000MΩ, the upper limit includes no upper limit setting
Accuracy 100-499V, 0.10MΩ~999.99MΩ, 1000~2000MΩ, ± (5%× setting +2 words)
500-2500V, 0.10~999.99MΩ, ± (2%× setting +2 words),
      1000~9999MΩ, ± (5%× setting +2 words)
      10000~50000MΩ, ± (15%× setting +2 words)