Technical Parameters – LIS 100A
|
W1
|
Coupling Mode
|
Cable Induction (CI)
|
Ground Injection (GI)
|
Module Selection
|
Wave 1-CI/GI
|
Wave 1-CI/GI
|
Current Waveform
|
6.4 μs ± 20 % / 69 μs ± 20 %
|
6.4 μs ± 20 % / 69 μs ± 20 %
|
Single-Stroke
|
25 A – 900 A +20%, -0%
|
25 A – 900 A +20%, -0%
|
Multiple-Stroke
|
25 A – 900 A +20%, -0% (First stroke);
25 A – 300 A +50%, -0% (Subsequent stroke)
|
25 A – 900 A +20%, -0% (First stroke);
25 A – 300 A +50%, -0% (Subsequent stroke)
|
No. of Subsequent Strokes
|
1 – 14 adjustable
|
1 – 14 adjustable
|
Time Intervals of Subsequent Strokes
|
10 ms – 200 ms adjustable, uniformity mode or random mode
|
10 ms – 200 ms adjustable, uniformity mode or random mode
|
Polarity
|
+, -;
|
+, -;
|
Current Coupling Device
|
LCT-1 (ratio of input/output turns: 3T:1T)
|
LCT-1 (ratio of input/output turns: 3T:1T)
|
No. of Tests
|
1 – 99
|
1 – 99
|
Test Repetition
|
30 s – 60 s
|
30 s – 60 s
|
EUT Load Capacity
|
/
|
AC 230 V, 16 A, 50 / 60 Hz, & DC
|
Technical Parameters – LIS 100A
|
W4
|
Coupling Mode
|
Cable Induction (CI)
|
Ground Injection (GI)
|
Module Selection
|
Wave 4-CI/GI
|
Wave 4-CI/GI
|
Voltage Waveform
|
6.4 μs ± 20 % / 69 μs ± 20 %
|
6.4 μs ± 20 % / 69 μs ± 20 %
|
Single-Stroke
|
10 V – 1,700 V +20%, -0%
|
10 V – 1,700 V +20%, -0%
|
Multiple-Stroke
|
10 V – 1,700 V +20%, -0% (First stroke);
10 V – 500 V +50%, -0% (Subsequent stroke)
|
10 V – 1,700 V +20%, -0% (First stroke);
10 V – 500 V +50%, -0% (Subsequent stroke)
|
No. of Subsequent Strokes
|
1 – 14 adjustable
|
1 – 14 adjustable
|
Time Intervals of Subsequent Strokes
|
10 ms – 200 ms adjustable, uniformity mode or random mode
|
10 ms – 200 ms adjustable, uniformity mode or random mode
|
Polarity
|
+, -;
|
+, -;
|
Current Coupling Device
|
LVT-1 (ratio of input/output turns: 5T:5T or 4T:4T)
|
LVT-1 (ratio of input/output turns: 5T:5T or 4T:4T)
|
No. of Tests
|
1 – 99
|
1 – 99
|
Test Repetition
|
30 s – 60 s
|
30 s – 60 s
|
EUT Load Capacity
|
/
|
AC 230 V, 16 A, 50 / 60 Hz, & DC
|