Grease capacity |
60 ml (2 US fl. oz) |
Nominal emptying time |
Adjustable; 1–12 months |
Ambient temperature range |
–20 to +60 °C (–5 to +140 °F) |
Maximum operating pressure |
5 bar (75 psi) (at start-up) |
Drive mechanism |
Gas cell producing inert gas |
Connection thread |
R1/4 |
Maximum feed line length with – grease |
300 mm (11.8 in.) |
Maximum feed line length with – oil |
1500 mm (59.1 in.) |
Intrinsically safe approval |
II 1 G Ex ia IIC T6 Ga, II 1 D Ex ia IIIC T85 °C Da, I M1 Ex ia I Ma |
EC Type Examination Certificate |
Kema 07ATEX0132 X |
Recommended storage temperature |
20 °C (70 °F) |