Measuring standard
|
FASTRACK RTLC: stainless steel tape scale with track mounting system
RTLC-S: stainless steel tape scale with adhesive backing, for mounting directly to a substrate without FASTRACK guide rails
|
Readhead size (LxHxW)
|
35 mm x 13.5 mm x 10 mm
|
Scale pitch
|
20 μm
|
Thermal expansion coefficient at 20 °C
|
10.1 ±0.2 μm/m/°C
|
Accuracy grade at 20 °C
|
±5 μm/m
|
Reference mark
|
IN-TRAC reference marks directly embedded into RTLC / RTLC-S
Selector magnet(s) used to identify one or more reference marks
|
Limit switches
|
Dual limits
|
Scale length
|
FASTRACK: 100 mm to 25 000 mm
RTLC: 20 mm to 10 000 mm
RTLC-S: 20 mm to 5 000 mm
|
Maximum speed
|
Up to 3.63 m/s
(See data sheet for details)
|
Sub-Divisional Error (SDE)
|
Typically <±10 nm
|
Dynamic signal control
|
Real time signal conditioning including Auto Gain Control (AGC), Auto Balance Control (ABC) and Auto Offset Control (AOC) for optimised performance across a range of operating conditions
|
Incremental signals
|
0.1 μm to 2.5 nm resolution
(See data sheet for details)
|
Electrical connection
|
0.5 m, 1 m, 1.5 m, 2 m and 3 m cable lengths with D-type connectors (9 and 15 pin) or circular in-line connector (12 pin)
|
Power supply
|
5 V -5%/+10%, typically <200 mA fully terminated
|
Vibration (operating)
|
100 m/s2 max at 55 Hz to 2 000 Hz
|
Shock (non-operating)
|
500 m/s2, 11 ms, ½ sine, 3 axes
|
Operating temperature
|
0 °C to +70 °C
|
Sealing
|
IP40
|