Versatile model for normally horizontal or inclined mounting and to have an electronic remote installation. The capacitive levels indicators ICS with the control unit ICU are to be used to control the maximum or minimum level of bulk solids in silos or vessels.
The model L-E3S has a Stainless Steel rod recovered of PTFE and the devices can have a shaft up to 2.000 mm length depending of the product to control.
It is not recommended for sticky solids or products that have the tendency to settle over probe.
Function:
The rod must to be exposed to the material. When the level of product reaches the rod, the control unit ICU reverses the signal due to a change of the capacity of the environment.
When the product disappear from the detection range, the signal turns to the initial position.
The control unit ICU has a regulation system that allow the adjustment of the sensitivity and a response time adjustment due to a nut in the electronic module.