Environmental |
Temperature range |
–50 to +120 °C (–60 to +250 °F), operating temperature |
Vibration limits |
500 g peak |
Shock limit |
5 000 g peak |
Electromagnetic sensitivity, equivalent g, maximum |
70 µg/gauss |
Sealing |
Hermetic |
Base strain sensitivity |
200 µg/microstrain |
CE |
According to the generic immunity standard for Industrial Environment EN50082-2 |
Acceptance criteria |
The generated “false equivalent g level” under the above test conditions should be less than 2 mg peak to peak |
Dynamic |
Sensitivity |
100 mV/g |
Sensitivity precision |
±5% at 25 °C (75 °F) |
Acceleration range |
80 g peak |
Amplitude linearity |
1% |
Frequency range |
±10%; 1,0 to 5 000 Hz, ±3 dB; 0,7 to 10 000 Hz |
Resonance frequency |
Mounted, minimum 22 kHz |
Transverse sensitivity |
≤ 5% of axial |
Electrical |
Power requirements |
Voltage source: 18 to 30 V DC, – Constant current diode: 2 to 10 mA DC, recommended 4 mA |
Electrical noise |
2,0 Hz; 20 µg/√Hz |
Output impedance |
< 100 Ω |
Bias output voltage |
12 V DC |
Grounding |
Case isolated, internal shielding |
|