The MW100 is a scalable, high performance data acquisition/data-logging platform designed for both PC-controlled and stand-alone operation under harsh operating conditions. Open Ethernet connectivity with web-based configuration and data monitoring functions allow MW100 to handle a wide range of monitoring and historical logging functions. See real time trends with your web browser from any PC and no special software. A full range of input/output modules handle all of your process inputs with fast measurement speed and high noise immunity for rock-solid performance.
Anytime, Anyplace...
- In a wide range of temperatures: -20 to 60° 1,2,3,4
- Reinforced insulation: Between input terminal and case5
3700 Vrms (one minute) or 600 Vrms/VDC (continuous)
- A wide variety of network functions: HTTP, FTP, DHCP, SNTP, E-mail, and others
- DC power supply (12 V-28 V) option available
Smart Logging...
- High speed measurement with a single unit (10 channels/10 ms or 60 channels/100 ms):
Shortest measurement interval of 10 ms
- Multi-interval: Enables mixing of three different measurement intervals in a single unit
(measurement intervals can be set for each module)
- Supports CompactFlash (CF) cards6 of up to 2 GB
Continuous data acquisition is possible on 60 channels at 100 ms for approximately ten days with a 2-GB card, or for three months on 60 channels at 1 s.
- MATH function on the main module available with the /M1 option.
- Collective data acquisition on 360 channels (via Modbus with the /M1 option)
- The operating temperature range for the input modules and main module. The operating temperature range of the output modules is -20 to 50°.
- Note that the power cord supplied with the main module differs depending on the operating temperature range (see the specifications on page 7). If the operating temperature range specification of the supplied standard power cord does not meet your requirements, we recommend that you select a screw-type terminal rather than the plug type for the main module power inlet, and supply your own power input cable.
- The operating temperature range of the AC adapter used with DC power supplies is 0 to 40°.
- Please consult with a representative for applications involving temperatures below -20°.
- The withstand voltage value with the MX110 input module. For the withstand voltage values of other input and output modules, please refer to the specifications for those modules (GS 04M10B01-01E).
- CF card not included (sold separately).
|