Accuracy (% of Reading) Factory Calibrated with Computer: ± 1.5%
Repeatability (based on test conditions): ± 0.2%
Pressure Rating: 300 PSI (21 Bar)
Operating Temp With Local Computer: 14°F to 140°F (-10°C to 60°C)
Operating Temp Without Local Computer or With Remote Computer: -40°F to 250°F (-40°C to 121°C) [Opt'l]
Max Pressure Drop (at Max Flow in test conditions): 7 PSI
Maximum Viscosity: 100 cps**
Recommended Strainer Size: 35 Mesh (500 Microns)
Max. Particle Size: .018" / .457 mm
5-Year Battery Powered; 6 Digit Display - Floating Decimal; Rate of Flow; Batch & Cumulative Totals; Factory Calibrated and Field Calibratable; Add-On Output Options; FM Approved Class I, Div. I; Choice of Gallons or Liters; Custom Programmable Display (including UOM)