Bronkhorst® EX-FLOW Mass Flow Meters (MFMs) are suited for precise gas flow measurement in ATEX Zone 1 hazardous areas. The MFM should be connected to a power supply with galvanic isolation / preamplifier / readout system (located in the safe zone). See Bronkhorst® E-8000 Series.
EX-FLOW model F-110CX covers flow ranges from 0,15...7,5 mln/min up to 0,2...10 mln/min (N2-equivalent) at operating pressures up to 100 bar.
The intrinsically safe measuring head of the flow meter is tested according to ATEX 114 Directive 2014/34/EU and approved under EC-Type Examination Number: KEMA 01ATEX1172, protection II 2 G Ex ib IIC T4 Gb.
ATEX approval Cat.2, Zone 1
Also IECEx and TIIS certified
Lowest gas flow ranges
Compact design, small internal volume
High accuracy
Virtually pressure and temperature independent
Thông số kỹ thuật
Electrical properties |
Signal circuit |
type of explosion protection: intrinsic safety Ex ib IIC, only for connection to a certified intrinsically safe circuit with the following maximum values:
Ui = 28 V, Ii = 98 mA, Pi = 686 mW
The effective internal capacitance between:
Terminals 1 and 3: Ci = 1 nF;
Effective internal inductance: Li = 0,3 mH |
Output signal |
15…20 mA (linear) |
I/O signals via PS/Readout
(located in safe area)
|
analog: 0...5 Vdc, 0...10 Vdc, 0...20 mA, 4...20 mA;
digital: RS232, PROFIBUS DP, DeviceNet™, Modbus RTU or ASCII, PROFINET, EtherCAT®, FLOW-BUS |