Many features are available that are a first in the power measurement industry *1
Measurement - High-precision, wide range, fast-sampling, simultaneous harmonic measurement
Voltage and current frequency bandwidth 5 MHz (-3 dB, typical)
Faster switching frequencies increasingly require measurements in a wider range. The WT1800 provides a voltage and current frequency bandwidth (5MHz) 5-fold wider than the previous measurement range and is capable of more correctly capturing fast switching signals.
Reduction of low power-factor error to 0.1% of apparent power (2/3 of previous model)
A power-factor error is one of the important elements to ensure high-accuracy measurements even at a low power factor. The WT1800 has achieved a power-factor error (0.1%) that is 2/3 of the previous model, in addition to a high basic power accuracy of ±0.1%.
Wide voltage and current range allowing direct input
Direct input of measurement signals makes it possible to measure very small current that can hardly be measured with a current sensor. The WT1800 provides a direct input voltage range from 1.5 V to 1000 V (12 ranges) and a direct input current range from 10 mA to 5 A (9 ranges) or from 1 A to 50 A (6 ranges).
0.1 Hz low-speed signal power measurement and max. 50 ms high-speed data collection
The frequency lower limit has been reduced to 0.1 Hz from the previous 0.5 Hz (5-fold lower than the previous model) to meet the requirement for power measurements at a low speed. Furthermore, high-speed data collection at a data update rate of up to 50 ms has been inherited. In addition to normal measurement data, up to the 500th order harmonic data can be measured and saved simultaneously. The data update rate can be selected from nine options from 50 ms to 20 s.
* Harmonic measurement at the 50 ms data update rate is possible up to the 100th order.
Particular voltage and current range selectable
Wide voltage and current input ranges have the advantage of extending the measurement application range. However, the downside is that the response time of the auto range tends to slow down. A range configuration function solves this problem. Since only the selected range (effective measurement range) can be used, the range can be changed up or down more quickly.
* Comparison with Yokogawa's previous model WT1600
*1: Applicable to a general-purpose high-precision three-phase power analyzer as of February 2011 (according to Yokogawa's survey).
Support for Energy Conservation Technologies and Sustainable Energy Development
|
Dual Harmonic Measurement
The perspective of the efficient use of energy is boosting demand for inverters to convert 50Hz or 60 Hz AC power to DC power, grid connection controllers to control reverse power flow occurring due to excess power, and battery chargers/dischargers. The WT1800 is capable of simultaneously measuring the harmonic distortion of the input and output current of these devices. Challenging the common wisdom that "harmonic measurement is limited to a single line," the WT1800 is capable of performing two-line simultaneous harmonic measurements. The WT1800 is also capable of measuring up to the 500th order harmonic even at high fundamental frequencies such as a 400 Hz frequency. |