The Ignitability Test Apparatus is manufactured to conform to ISO 5657 and BS 476; Part 13. The Apparatus has been designed, principally for testing building materials and composites, but it is capable of testing any sample of size 165mm × 165mm and up to a maximum of 70mm thick. The Apparatus measures the ignition characteristics of exposed surfaces of essentially flat materials and specimens.
Main Features:
The sample orientation is horizontal
Irradiation levels between 10-50 kW/m2 using a conical radiation furnace
Furnace is controlled by 3 term temperature controller
Temperature indicator and over temperature device
Fitted with pilot flame with provision for re-ignition
Mechanism to bring pilot flame into the correct position above the plane of sample every 4 seconds
Separate support frame and control unit Supplied complete with Flux Meter
Supply Requirements:
Voltage: 240V- 50/60 Hz -15A
Gas: Propane and Air for the pilot flame
Water: For cooling the Flux Meter
|