Hotline: 0984.843.683 Email: info@ttech.vn  Zalo: 0984.843.683

Line Quantum Sensor LI-191R LI-COR

Mã sản phẩm: LI-191R
Sử dụng cho Model: LI-191R, LI-191R giá tốt, báo giá LI-191R, LI-191R giá rẻ, Line Quantum Sensor LI-COR
Hãng SX: LI-COR
Xuất xứ
Bảo hành
Tình trạng

Tình trạng: Còn hàng

Đặt hàng
Line Quantum Sensor
Model: LI-191R
Hãng: LI-COR

Liên Hệ Hỗ Trợ

    • SĐT: 0984 843 683

    • Mail: info@ttech.vn

      • Zalo: 0984.843.683

Thông tin sản phẩm

The LI-191R Line Quantum Sensor measures PAR integrated over its 1-meter length. It is used to measure sunlight under a plant canopy, where the light field is non-uniform. The LI-191R makes it easy to measure under-canopy light in many plots quickly and consistently. It measures light in units of Photosynthetic Photon Flux Density (PPFD), which is expressed as μmol s-1 m-2.

The LI-191R uses a 1-meter long quartz rod under a diffuser to direct light to a single filtered silicon photodiode. The entire LI-191R diffuser is sensitive to light over its 1-meter length. Since the diffuser is one continuous piece, the LI-191R essentially integrates an infinite number of points over its surface into a single value that represents light from the entire 1-meter length. Optical filters block radiation with wavelengths beyond 700 nm, which is critical for under-canopy measurements, where the ratio of infrared to visible light may be high. The unique design of the LI-191R provides an excellent quantum response that is close to the ideal quantum response.

LI-191R Specifications
Absolute Calibration: ± 10% traceable to National Institute of Science and Technology (NIST). The LI-191 is calibrated via transfer calibration using a reference LI-190R Quantum Sensor. Transfer error is ± 5% (included in the ± 10%)
Sensitivity: Typically 7 μA per 1,000 μmol s-1 m-2
Linearity: Maximum deviation of 1% up to 10,000 μmol s-1 m-2
Response Time: 10 μs
Temperature Dependence: ± 0.15% per °C maximum
Cosine Correction: Acrylic diffuser
Azimuth: < ± 2% error over 360° at 45° elevation
Operating Temperature Range: −40 °C to 65 °C
Relative Humidity Range: 0% to 95% RH, Non-Condensing
Sensitivity Variation over Length: ± 7% maximum using a 2.54 cm (1”) wide beam from an incandescent light source.
Sensing Area: 1 m × 12.7 mm (39.4” × 0.50”)
Detector: High stability silicon photovoltaic detector (blue enhanced)
Sensor Housing: Weatherproof anodized aluminum housing with acrylic diffuser and stainless steel hardware.
Size: 121.3 L × 2.54 W × 2.54 cm D (47.7” × 1.0” × 1.0”)
Weight: 1.4 kg (3.0 lbs.)
Cable Length: 3.1 m (10.0 ft.)