Versatile: The ROMER Absolute Arm 71 series provides the base for your own made-to-measure metrology solution. A broad choice of accessories makes the arm ready for new applications at any time.
Complete system certification: For trustworthy measurement results.
Ease of use: The ROMER Absolute Arm is counterbalanced so it moves naturally with the user.
Mobility pack (optional): Adds WiFi connection and battery operation to the ROMER Absolute Arm. Measurement without cables gives greater flexibility and safety in workshop environment.
Mounting ring adapter (optional): With a simple upgrade, the 71 series is compatible to all ROMER Absolute Arm bases and stands that use a threaded mount.
Integrated base: Easy to mount on any table or workbench, even if it‘s not perfectly level.
State of the art Absolute Encoders: No referencing required at start-up. Switch on the arm and measure, wherever you are.
RDS: A common software platform for all ROMER Absolute Arms with access to user friendly checking and calibration routines.
Compatible with all major portable metrology software packages, including PC-DMIS Touch.
TKJ-Adapter (optional): Get instant access to all ROMER Absolute Arm compatible probes. Thanks to automated probe recognition, it removes the need for probe calibrations.
Carbon fibre: For maximum stability and reliability.
Model |
Measuring Range Probing |
Point Repeatability¹ |
Volumetric Accuracy² |
Arm weights (incl. base) |
7125 |
2.5 m (8.2 ft) |
0.050 mm (0.0020 in) |
0.069 mm (0.0027 in) |
7.9 kg (17.42 lb) |
7325 |
3.5 m (11.5 ft) |
0.103 mm (0.0041 in) |
0.141 mm (0.0056 in) |
8.3 kg (18.30 lb) |
¹ The Point Repeatability Test is the reference test to determine measurement arm repeatability with ball probe. The cone is placed in front of the machine. Points are measured from multiple approach directions. The average point and the deviation of each point to the average center are calculated. The result is the maximum range divided by two.
² The Volumetric Accuracy Test most accurately represents the reasonable expectations for machine performance in practical measuring applications since it involves measuring a certified length standard many times in several locations and orientations and compares the resultant measurements to the actual length. The Volumetric Length Accuracy Test is the most appropriate test for determining machine accuracy and repeatability. The result is the maximum deviation of the measuring distance less the theoretical length.