Response of the third harmonic fi lter:
. < - 60 dB at 50 Hz;
. 0 dB at 150 Hz;
. < - 20 dB at 250 Hz and higher frequencies.
On request (60 Hz networks):
. < - 60 dB at 60 Hz;
. 0 dB at 180 Hz;
. < - 20 dB at 300 Hz and higher frequencies.
Accuracy
50 Hz measure, rms and peak value: total maximum of ± 5% from 0.1 to 10 mA.
150 Hz rms measure: total maximum of ± 10% from 10 to 1000 µA.
On request (60Hz networks).
60 Hz measure, rms and peak value: total maximum of ± 5% from 0,1 to 10 m A.
180 Hz rms measure: total maximum of ± 10% from 10 to 1000 µA.