mini CORI-FLOW™ Mass Flow Meters and Controllers are precise and compact instruments, based on the Coriolis measuring principle, designed to cover the needs of the low flow market. Bronkhorst® model M14V10I Mass Flow Controller (MFC) is suited for highly accurate control of gas flow ranges between 0,03…1 kg/h and 0,6…30 kg/h (which corresponds with 0,4…13,3 ln/min up to 8…400 ln/min when used on nitrogen) at operating pressures up to 100 bar (higher on request). The instruments are equipped with a robust IP65 weatherproof housing and are optionally available with ATEX approval for use in Zone 2 hazardous areas.
Thông số kỹ thuật
Measurement / control system |
Mass flow accuracy |
±0,5% of rate |
Turndown |
≥ 1:50 |
Repeatability |
±0,05% of rate ± ½(ZS* x 100/flow)% based on digital output |
Zero Stability (ZS)* |
< ±6 g/h |
Settling time (<2% of setpoint) |
1 sec. (typical) |
Max. Kv-value |
1,7 x 10-2 |
Operating temperature |
0…70°C;
for ATEX Cat.3, Zone 2 max. 50°C |
Temperature effect** |
on zero: < 0,5 g/h/°C;
on span: < 0,001% Rd/°C;
self heating (at zero flow): ≤ 15°C |
Temperature accuracy |
±0,5°C |
Density accuracy |
< ±5 kg/m3 |
Mounting*** |
Any position, attitude sensitivity negligible |
Leak integrity (outboard) |
< 2 x 10-9 mbar l/s He |
Warm-up time |
> 30 min. for optimum accuracy |
|