Hotline: 0984.843.683 Email: info@ttech.vn  Zalo: 0984.843.683

Multiple Gas Analyzer #2 GC - SRI

Mã sản phẩm: Multiple Gas Analyzer #2 GC
Sử dụng cho Model:
Hãng SX: SRI
Xuất xứ
Bảo hành
Tình trạng

Tình trạng: Còn hàng

Đặt hàng

Multiple Gas Analyzer #2 GC

Maker : SRI

Yêu Cầu Giá Tốt

Thông tin sản phẩm

Multiple Gas Analyzer #2 GC

Maker : SRI

  • Separates a wide variety of peaks in a single injection, including water
  • Tolerant of user adjustments and timing variations
  • Simpler than other multiple gas capable systems

The basic MG#2 model includes:

  • TCD detector
  • molecular sieve 13X & HayeSep D packed columns 
  • 10-port gas sampling valve and dual loops
  • 1 channel PeakSimple data system on the compact 8610C chassis
 
Multiple Gas Analyzer #2 GC system (MG#2) is pre-plumbed and ready to resolve H2, O2, N2, methane, CO, ethane, CO2, ethylene, water, alcohols, propane, butanes, pentanes and C6. The MG#2 is similar to the MG#1, except that the MG#2 can measure water and alcohol in addition to the multiple gas compounds. This configuration has since been superseded by the MG#3 series GCs, offering improved performance at a lower price.

 
To separate such a wide variety of peaks without co-elution, the MG#2 turns on the carrier gas flow to each column at different times during the run. This allows the Molecular Sieve column to complete the separation of H2, O2, N2, CH4 and CO, at which point the molecular sieve carrier flow is turned off and the HayeSep-D carrier flow is turned on. The HayeSep D column then separates all compounds in the C1-C6 range. An optional capillary column in parallel with the HayeSep-D and connected to an additional optional FID detector (additional $3,088, plus $2,879 data system upgrade, if needed) can also be useful in separating the hydrocarbons out through C20. Detectors can be TCD, HID, FID, or any combination, depending on your application needs.

 

This chromatogram shows the separation of a 1% Gas Standard sample on a MG#2 equipped with a TCD detector. The first five peaks came off the molecular sieve column, and the following three peaks came off the HayeSep D column. Note that the methane elutes twice, once from each column.

These two chromatograms show the separation of a 1000 ppm C1-C6 standard plus room air on a MG#2 GC equipped with TCD (bottom chromatogram) and FID (top chromatogram) detectors.

 

This modified MG#2 (8610-0271) is equipped with:

TCD detector
optional HID detector
FID-methanizer
optional 30 meter capillary column
molecular sieve 13X & HayeSep D packed columns
10-port gas sampling valve and dual loops
6 channel PeakSimple data system

 


Bình luận

Sản phẩm khác

Geoprobe™ GC - SRI

Geoprobe™ GC - SRI

Prezzo Pieno:

Liên hệ

Mua ngay

Explosives GC System - SRI

Explosives GC System - SRI

Prezzo Pieno:

Liên hệ

Mua ngay

Dissolved Gas Analyzer GC - SRI

Dissolved Gas Analyzer GC - SRI

Prezzo Pieno:

Liên hệ

Mua ngay

Educational FID GC - SRI

Educational FID GC - SRI

Prezzo Pieno:

Liên hệ

Mua ngay

Educational TCD GC System - SRU

Educational TCD GC System - SRU

Prezzo Pieno:

Liên hệ

Mua ngay

Capillary FID GC - SRI

Capillary FID GC - SRI

Prezzo Pieno:

Liên hệ

Mua ngay

Biodiesel GC - SRI

Biodiesel GC - SRI

Prezzo Pieno:

Liên hệ

Mua ngay

310 Soil Gas GC System - SRI

310 Soil Gas GC System - SRI

Prezzo Pieno:

Liên hệ

Mua ngay