Hotline: 0984.843.683 Email: info@ttech.vn  Zalo: 0984.843.683

Nguồn cấp AC/DC cho máy bay tại sân đỗ mặt đất Ainuo

Mã sản phẩm: AN17CP
Sử dụng cho Model:
Hãng SX: Ainuo
Xuất xứ
Bảo hành
Tình trạng

Tình trạng: Còn hàng

Đặt hàng
Integrated AC/DC Aircraft Ground Static Converter
Model: AN17CP
Hãng: Ainuo

Liên Hệ Hỗ Trợ

    • SĐT: 0984 843 683

    • Mail: info@ttech.vn

      • Zalo: 0984.843.683

Thông tin sản phẩm

Thông số kỹ thuật

Model

AN17CP(115V/400HZ+DC270V)

AN17CP(115V/400HZ+DC28V)

Input

Phase

Three-phase three-wire+PE

Voltage

380V/400V±15%

Frequency

45~63Hz

Line Current Distortion

<8.5%

Power Factor

>96%(100%load)

Impact Current

None,with soft start

AC Output

Phase

Three-phase four-wire

Output Voltage

3×200/115V

Output Power

0~90KVA

Power Factor

0.7 lag,0.95 advanced

Voltage regulation

<0.5%(balance load or 30% unbalanced load)

Total harmonics

Linear load <1.5%
Non-linear load per ISO1540

Crest factor

1.414±3%(±0.042)

Voltage modulation

<1.0%(Typical<0.5%)

Phase angle symmetry

120°±1°(balance load):120°±2°(30% unbalanced load)

Frequency

400Hz±0.1%

Overload

Work for 600 Sec.with 125% overload;60 Sec.with 150% load.;10 Sec.with 200% load.

DC Output

Rated Voltage

270VDC

28.5V

Rated Curren

250A

800A

Steady Voltage Range

260~280V

24~29V

Output Voltage Range

230~310V

20~32V

Overload

Work for 300 Sec.with 125% overload

Work for 30 Sec.with overload 1200A

10 Sec.with overload 1800A

5 Sec.with overload 2100A

2 Sec.with overload 2400A

 

waveform

Voltage distortion coefficient:0.005

Voltage distortion coefficient:0.5%

Pulse amplitude:≤3V

Pulse amplitude:1%

Protect

Input under/over voltage,input phase sequence;

Key unit overheat;

Main power supply monitoring;

Output under/over voltage (GJB572A standard);

Output overload,output short circuit

Environment

Operating temperature

-40℃-+55℃

Relative humidity

10%-95%

Noise level

<65dB(A)(1m),general 60dB(A)

Protection grade

IP55(outdoor)

Service life

Service life

>25 years

Mean Time Between Failure(MTBF)

Invention Part:>25000 hours

 

Ventilation Part:>100000 hours

 

Mean Time to Restoration(MTTR)

<20 Min.

Remarks

It can not output 115V/400Hz and 270VDC simultaneously

When outputting 28.5VDC ,115V/400Hz can be used at most 10KW

Technical specification testing temperature:25℃±5℃

Xem thêm: AN17PC090-25B


Bình luận