- The Nova 320 Series of Portable Flue Gas Oxygen Analyzers utilize a reliable, stable oxygen sensor which responds quickly to the oxygen present in a flue gas sample. Its life expectancy is between 3 and 4 years. The sensor is very easy for the customer to replace and at a reasonable cost.

- A rechargeable ‘gel cell’ battery provides enough power for the pump and electronics for about 20 hours of continuous operation. The analyzer can still be operated while it is being charged. A red LED indicates when to recharge and a green LED indicates that it is receiving recharging power. The analyzer is supplied with a 12 ft. sample hose and a stainless steel probe.

- The Model 320 can optionally indicate stack temperature (Model 320T; 0-1800°F or 0-1000°C) for doing fuel efficiency calculations. The temperature sensor is built into the sampling probe. Efficiency charts for each fuel are provided.

- Rugged design that is easy to operate and maintain
- Fast warm-up and response
- Long life 'fuel cell' oxygen sensor (3-4 year life)
- Digital readout meter with backlight
- Rechargeable battery operation
- Built in sample pump, filter and flow meter
- Continuous condensate removal
- For use on any fuel
- Weatherproof (WP) cabinet with clear Lexan cover
- Stainless steel probe with sample hose
- Pays for itself in months through fuel savings

Thông số kỹ thuật

- Method of Detection : Long life electrochemical oxygen sensor
- Ranges Available : 0-5.0%, 0-10.0%, 0-25.0%, 0-50.0%
- Resolution : 0.1% O2
- Accuracy & Repeatability : ±1% of full scale (±2% of full scale above 30% O2)
- Drift : < 2% of full scale for 8 hours of operation
- Response Time (T-90) : 8-10 seconds for 90% of step change
- Ambient Temperature Range : 0 to 40 ºC; 32 to 105 ºF
- Linearity : ±1% of full scale
- Size & Weight : 14" L x 6" H x 10 1/2" D @ 8 lbs (35.5 x 15.2 x 26.6 cm @ 3.6 kg)
- Power : AC/DC Operation, 115 VAC, 60 Hz for recharging (Other voltages available)
- Output Options : 0-1 V or 4-20 mA (optional)
- Hazardous Area Rating Options : General Purpose, Non-Hazardous