Quantaurus-Tau Fluorescence lifetime spectrometer
Model: C11367-31
Hãng: Hamamatsu

Yêu Cầu Giá Tốt

Thông tin sản phẩm

The Quantaurus-Tau is a compact system for quickly and easily measuring the fluorescence lifetime of photoluminescent materials from sub-nanoseconds to the millisecond range, with single-photon-counting sensitivity. Samples in different forms―thin films, solids, powders, and solutions―can be analyzed. Liquid samples can be cooled down to -196 deg.C (77K) with liquid nitrogen.
Operation is simple. Just load the sample into the sample chamber. Then enter a few conditions on the measurement software to measure the fluorescence lifetime and photoluminescence (PL) spectrum. It only takes a minute to get analysis results for a typical measurement. The measurement software includes a variety of measurement and analysis functions such as multicomponent analysis and multisample data comparison.

The fluorescence spectrum obtained from an organic material or fluorescent probe is a vital parameter for controlling and evaluating the material functions and characteristics such as the peak wavelength and fluorescence intensity. However, a fluorescence spectrum usually shows time-integrated information, and so when the material contains multiple substances and reactive elements, their fluorescence spectrum can only be acquired as integrated information. An effective approach in such cases is to observe the light emission dynamics by making use of the time axis parameter. This is generally called fluorescence lifetime measurement, in which the time required for the substance excited by the pulsed light to return to its ground state is measured in the sub-nanosecond to millisecond region. This measurement allows obtaining more information such as multiple different fluorescence lifetimes even at the same wavelength and the percentage in which they are present within the material, etc.

●Easy and quick measurements

Emission Lifetime can be gotten easily and quickly only by putting the sample into sample box and setting the 4 measurement conditions.

●7 excitation wavelength

280 nm, 340 nm, 365 nm, 405 nm, 470 nm, 590 nm, or 630 nm.
●Analyzing different sample forms

Thin-film, solid, solutions and powder.
●Wavelength: 300 nm to 800 nm
●High sensitivity measurement by photon counting method
●Time resolution better than 100 ps (by deconvolution)
●Cooling function for solution sample (-196 °C) (option)
●Phosphorescence measurement (option)
●Fluorescence spectrum measurement
●Space-saving, compact design