Matching "initial curing rubber compound Laid GB / T1232" unvulcanized rubber Mooney viscosity measurement ", GB / T1233 requirements of Mooney Viscometer" and ISO289, ISO667 and other standards. For measuring the raw rubber mixture or batch viscosity, scorch and cure index. Computer control, data, automatic calibration, rubber industry ideal experimental apparatus and research institutes. Imported intelligent digital temperature controller, easy to adjust settings, temperature wide range. Use the latest principles to use the "host + computer + printer" structure. Computer control and connection interface board for data collection, storage, processing and printing test results and curves. Software platform is Windows 98 / Me / NT / XP and other versions, visual graphics software window interface, the digital processing more accurate, the operation as a simple, flexible and convenient. High reliability, fully reflects the highly automated features.
Technical parameters:
1. Temperature range: room temperature -200 °C
2. Temperature fluctuation: ± 0.5 °C
3. Mooney measurement range: 200 full-scale Mooney value
4. Mooney value resolution: 0.1 Mooney value
5. Mooney measurement accuracy: ±0.5 Mooney value
6. Rotor speed: 2±0.02 r/min
7. Power supply: AC220V 50Hz
8. Dimensions: 660mm×570mm×1300mm
9. Host weight: 210kg