| Measuring Range with FH4 Probe | 
            0 - 6 mm (0 - 0.236"), refer to Probe Type Table above for additonal details of ball sizes needed for measurement | 
        
        
            | Measuring Range with FH4-1MM Probe | 
            0 - 6 mm (0 - 0.236"), refer to Probe Type Table above for additonal details of ball sizes needed for measurement (Includes additional calibration with 1mm diameter non-magnetic balls for use in small concave areas) | 
        
        
            | Measuring Range with FH4-M Probe | 
            0 - 9 mm (0 - 0.345"), refer to Probe Type Table above for additonal details of ball sizes needed for measurement | 
        
        
            | Measuring Range with FH10 Probe | 
            0 - 13 mm (0 - 0.512"), refer to Probe Type Table above for additonal details of ball sizes needed for measurement | 
        
        
            | Measuring Range with FH10-M Probe | 
            0 - 24 mm (0 - 0.945"), refer to Probe Type Table above for additonal details of ball sizes needed for measurement | 
        
        
            | Accuracy with FH4 Probes | 
            0-1.5mm: ±(3 µm + 1% of reading) 
            0-2.5mm: ±(5 µm + 1% of reading) 
            0-4.0mm: ±(10 µm + 1% of reading) | 
        
        
            | Accuracy with FH10 Probes | 
            0-4.0mm: ±(5 µm + 1% of reading) 
            0-7.0mm: ±(10 µm + 1% of reading) 
            0-10.0mm: ±(20 µm + 1% of reading) 
            0-13.0mm: ±(20 µm + 1% of reading) 
            0-16.0mm (magnetic): ±(40 µm + 2% of reading) 
            0-24.0mm (magnetic: ±(60 µm + 2% of reading) | 
        
        
            | Low Range Resolution | 
            FH4: 0.1 µm 
            FH10: 0.2 µm | 
        
        
            | Repeatability | 
            Better than ± (1 µm + 0.5 % of reading) | 
        
        
            | Measuring Principle | 
            Magnetostatic | 
        
        
            | Logging Rate | 
            1, 2, 5, 10, 20 readings per second (selectable) | 
        
        
            | Data Memory | 
            FH7200: 100,000 values 
            FH7400: 240,000 values | 
        
        
            | Calibration Modes | 
            Factory, Zero, Zero + up to 4 points | 
        
        
            | Measuring Units | 
            Metric: µm, mm 
            Imperial mils, inch | 
        
        
            | Statistical Charting | 
            Numeric, trend, and histogram (with MiniTest 7400 FH only) | 
        
        
            | Interfaces | 
            USB + IrDA 1.0 | 
        
        
            | Operating temperature | 
            -10 °C to +60°C (Storage temperature: -20°C to +80°C) | 
        
        
            | Dimensions | 
            153 mm x 89 mm x 32 mm | 
        
        
            | Weight | 
            310 grams |