Range in Steel: |
Pulse-Echo Mode: Pit and Flaw detection measures from 0.025 - 9.999inches (0.63 to 254 millimeters)
Echo-Echo Mode: Thru Paint & coatings measures from 0.100 - 4.000 inches (2.54 to 102 mm). Range will vary depending on the thickness |
Range in Coating Only Mode |
0.0005" - 0.1000" / Resolution: 0.0001"
(0.013 - 2.540 mm / Resolution: 0.001 mm) |
Max Coating |
0.100" (2.54mm) |
Resolution: |
.001 inches (0.01mm) |
Velocity Range: |
.0492 to .3936 in./ms
1250 to 9999 meters/sec |
Units: |
Inch or mm |
Measurement Modes: |
- Pulse-Echo (corrosion mode)
- Pulse-Echo Coating (Corrosion w/o coating)
- Echo-Echo (thru-paint)
- Temp Comp (auto adjust for material temp)
- Coating Only (Ultrasonic Coating Gauge) |
Transducer Types: |
Dual Element (1 to 10 MHz). |
Output |
RS-232 for upload/download of setups |
Memory capacity: |
TI-CMX: None
TI-CMXDL: over 200,000 measurements |
Power Source: |
Three 1.5V alkaline or 1.2V NiCad AA cells |
Battery Life: |
Typically operates for 150 hours on alkaline and 100 hours on NiCad |
Auto Power off: |
After 5 minutes of non-use |
Display: |
1/8 in. VGA grayscale display 62 x 45.7mm |
Keyboard: |
Membrane switch with twelve tactile keys |
Case: |
Extruded aluminum body with nickel-plated aluminum end caps (gasket sealed). |
Temp. Limits |
Ambient: -20 to 120° F (-30 to 50° C)
Material: -0 to 200° F (-20 to 100° C)
Special high temperature model TI-CMX-H is available for 300°F/150°C and optional probes are offered for higher surface temperatures |
Weight, net: |
383 grams |
Dimensions: |
63.5 W x 165 H x 31.5 D mm |