Hotline: 0984.843.683 Email: info@ttech.vn  Zalo: 0984.843.683

Thiết bị đo cường độ UV UV-37SD Custom

Mã sản phẩm: UV-37SD
Sử dụng cho Model:
Hãng SX: Custom
Xuất xứ
Bảo hành
Tình trạng

Tình trạng: Còn hàng

Đặt hàng

- In addition to the ultraviolet rays UVA · UVC, data recording is also possible to connect the K / J-type thermocouple sensor (sold separately) to the temperature measurement / SD card.

- Since the recording data is available in commercially available spreadsheet software, you can take advantage of a variety of applications.

- Data recording, can be selected from the automatic recording / manual recording. 

- Sampling set time of automatic data logger can be set arbitrarily than 1,2,5,10,30,60,120,300,600,1800,3600 seconds.

Liên Hệ Hỗ Trợ

    • SĐT: 0984 843 683

    • Mail: info@ttech.vn

      • Zalo: 0984.843.683

Thông tin sản phẩm

Ultraviolet rays


  range resolution Measurement accuracy
UVA / UVC ~ 1.999MW 0 / Cm 2 0.001MW / Cm 2 ± (4% FS + 2dgt)
~ 20.00MW 2.00 / Cm 2 0.01MW / Cm 2


FS = full scale (full scale)


Recommended to be measured ultraviolet wavelength


type wavelength
UVA sensor 320 ~ 380nm (calibration ultraviolet wavelength: 365nm)
UVC sensor 200 ~ 280nm (calibration ultraviolet wavelength: 254nm)


Please use to measure the ultraviolet light of the wavelength of each of the sensor is above. UVC sensor ultraviolet wavelengths other than the 200 ~ 280nm to the light to be measured at the time of use were included: If you measure (for example, natural light, etc.), it may not be measured correctly. 
Device using the wavelength containing UVA region (an example): tanning bed, reptiles breeding lighting, plate making lamps, black light, etc. 
with a wavelength including a region of UVC device (one example): Watching Fish sterilizing filter, athlete's foot ultraviolet light therapy equipment, germicidal lamp, etc.


Temperature


type Measurement range resolution Measurement accuracy
K type -50.0 ~ + 1300.0 ℃ 0.1 ℃ ± (0.2% rdg + 0.5 ℃)
-100.0 ~ -50.1 ℃ ± (0.2% rdg + 1 ℃)
J type -50.0 ~ + 1100.0 ℃ 0.1 ℃ ± (0.2% rdg + 0.5 ℃)
-100.0 ~ -50.1 ℃ ± (0.2% rdg + 1 ℃)

  • It does not include the option of sensor accuracy in the measurement accuracy.
  • There is no handling of the J-type thermocouple sensor at our company.


General specification


Use temperature and humidity

0 ~ + 50 ℃, 80% RH or less (without condensation)

Storage temperature and humidity -20 ~ + 60 ℃, 85% RH or less (without condensation)
Size

Body: W68 x H177 x D45mm,

UVA Sensor: probe head φ45 × 32mm, handle φ24 × 125mm, about the time code telescopic 350mm

UVC sensor: φ38 × 27mm, about the time code telescopic 350mm

weight

Body: about 350g (including battery),

UVA · UVC sensor: about 100g

Power supply AA batteries × 6 or AC adapter (sold separately)
accessories Manual, UVA sensor, UVC sensor
Proofreading Yes
option

AC adapter: VSM-932EK

K-type thermocouple sensor: LK model number of the product

JAN 4983621230376



About SD card

  • It supports commercially available SD card (1 ~ 16GB), but the operation authentication for the SD card product of all manufacturers is not done. Because there may not be accustomed to the use by SD card, please note.
  • SD card is not included in the product. Please purchase separately.
  • SDXC type of memory card of the card and MMC Nadohoka can not be used.
  • SDXC, SDHC is a registered trademark of the SD Association.

Bình luận