ETS-Lindgren's Model HI-6153 Laser-powered Electric Field Probes provide broadband EMF frequency coverage and wide dynamic range that satisfies the demands of most test requirements. To take advantage of this capability, the HI-6153 was designed to be single range reading so data can be read continuously over the entire dynamic range. Data values for each axis (X,Y,Z) can be read individually, or summed.
Fiber optic signal and power lines link the model HI-6153 probe to either the model HI-6100 Field Monitor, or as a direct connect to a PC USB port with the HI-6113 Laser Data Interface and ProbeView™ Laser Software.
The HI-6100 provides manual functions and programmed control via IEEE-488 and RS-232 Serial Data Interfaces. Readings from up to four probes can be displayed simultaneously.
The EMCenter™ Modular RF Platform along with the EMSense™ interface card can be used with the HI-6000 series field probes as a field monitor in addition to its capability as a system level platform.
The HI-6113 provides the laser power and communications for the HI-6153. A USB connection to the PC allows for quick and easy data collection, using ProbeView Laser software.
Laser Powered for Unlimited Test Time
Frequency Range: 10 MHz to 40 GHz
Dynamic Range: 2.0 to 800 V/m (Single Range)
Provides Individual and Summed Axis Values
A2LA Accredited Calibration Report
Electrical Specifications
Detection Isotropic: (X, Y, and Z Axis Readings)
Frequency Range: 10 MHz to 40 GHz
Frequency Response with Correction:
10 MHz to 18 GHz ± 0.9 dB
18 to 40 GHz ± 1.1 dB
Frequency Response (Typical):
10 to 100 MHz + 3.0, -4.0 dB
100 MHz to 1 GHz +3.0, -0.50 dB
1 to 18 GHz +4.0, -2.0 dB
18 to 40 GHz +3.5, -4.5 dB
Dynamic Range: 2 to 800 V/m (Single Range)
Resolution: 0.01 V/m
Isotropic Deviation: ±1.0 dB < 18 GHz
Linearity: ±0.5 dB
Sample Rate (Typical): 70 Samples per Second Maximum
Overload Withstand: >1500 V/m CW