Measuring range:
0.1 - 1 l/h ... 20 - 200 l/h water
5.0 - 50 Nl/h ... 600 - 6000 Nl/h air
Connection: ¼" NPT
Material: stainless steel
pmax: 40 bar (64 bar), up to 420 bar on request
Max. Temperature: -40 ... +130°C
Contact: -25 ... +100°C, analogue output: -40 ... +100°C
Accuracy: ±3 % of full scale
Option: contacts, analogue output, up / downstream pressure regulator
|