| General information |
| |
Article number |
3.510.260.013 |
| Air temperature [°C] |
| |
Measuring principle |
NTC |
| |
Min. measuring range [°C] |
-20 |
| |
Max. measuring range [°C] |
50 |
| |
Display resolution [°C] |
0.1 |
| Relative humidity |
| |
Measuring principle |
Capacitive |
| |
Min. measuring range [% RH] |
10 |
| |
Max. measuring range [% RH] |
95 |
| |
Accuracy ± [% RH] |
2 |
| |
Display resolution [% RH] |
0.5 |
| Air pressure |
| |
measuring principle |
|
| |
Measuring range [hPa] |
|
| |
Accuracy ± [hPa] |
|
| |
Display resolution [hPa] |
|
| CO₂ concentration |
| |
Measuring principle |
NDIR |
| |
Measuring range [ppm] |
0 - 5,000 |
| |
Accuracy |
± 50 ppm / + 3% of measured value (at 20°C and 1,013 mbar) |
| |
Display resolution [ppm] |
1 |
| |
Long-term stability [ppm/a] |
20 |
| Voltage input |
| |
Min. measuring range [V] |
|
| |
Max. measuring range [V] |
|
| |
Accuracy ± [µV] |
|
| |
Accuracy of the measured value - Voltage input ± [%] |
|
| |
Resolution |
|
| Current measurement |
| |
Min. measuring range in two-wire operation [mA] |
|
| |
Max. measuring range in two-wire operation [mA] |
|
| |
Min. measuring range in three-wire operation [mA] |
|
| |
Max. measuring range in three-wire operation [mA] |
|
| |
Accuracy ± [µA] |
|
| |
Accuracy of the measured value ± [%] |
|
| |
Resolution [µA] |
|
| |
Approx. output load [Ω] |
|
| Thermal element K |
| |
Min. measuring range [°C] |
|
| |
Max. measuring range [°C] |
|
| |
Accuracy Between -200 °C ... 0 °C [°C] |
|
| |
Accuracy Between -200 °C ... 0 °C [°C] - Of measured value |
|
| |
Accuracy Between 0 °C ... 1,200 °C [°C] |
|
| |
Accuracy Accuracy between 0 °C ... 1,200 °C [°C] - Of measured value |
|
| |
Resolution [°C] |
|
| Thermal element J |
| |
Min. measuring range [°C] |
|
| |
Max. measuring range [°C] |
|
| |
Accuracy -200 °C ... 0 °C [°C] |
|
| |
Accuracy -200 °C ... 0 °C [°C] - Of measured value |
|
| |
Accuracy Accuracy between 0 °C ... 1,200 °C [°C] |
|
| |
Accuracy Accuracy between 0 °C ... 1,200 °C [°C] - Of measured value |
|
| |
Resolution [°C] |
|
| Thermal element S |
| |
Min. measuring range [°C] |
|
| |
Max. measuring range [°C] |
|
| |
Accuracy Between -50 °C ... 0 °C [°C] |
|
| |
Accuracy Between -50 °C ... 0 °C [°C] - Of measured value |
|
| |
Accuracy 0 °C ... 1,700 °C [°C] |
|
| |
Accuracy 0 °C ... 1,700 °C [°C] - Of measured value |
|
| |
Resolution [°C] |
|
| PT100 |
| |
Min measuring range [°C] |
|
| |
Max. measuring range [°C] |
|
| |
Accuracy [°C] |
|
| |
Accuracy of the measured value ± [%] |
|
| |
Resolution [°C] |
|
| Interface |
| |
LAN |
|
| |
USB |
|
| |
Plug socket |
|
| |
BNC |
|
| |
RS-485 |
|
| |
10-pin terminal |
|
| Power supply |
| |
Internal (battery) |
4 x 1.5 V, AA, operating time > 1 year (depending on sensor and configuration) |
| |
External (USB) |
|
| |
External (LAN, PoE model) |
|
| |
Terminals for external power supply to supply the sensor |
|
| Display |
| |
Size [mm] |
90 x 64 |
| |
LCD |
|
| Memory organisation |
| |
Sensing interval |
10/30 s, 1/10/12/15/30 min, 1/3/6/12/24 h |
| |
Saving interval |
1/10/12/15/30 min |
| |
Memory |
16 MB, 3,200,000 measured values |
| |
Data logging |
Up to 20 measurement channels in parallel |
| |
Available measurement channels |
28 |
| |
Available channel groups |
7 |
| Housing design |
| |
Plastic |
|
| Dimensions |
| |
Length (packaging excluded) [mm] |
166 |
| |
Width (packaging excluded) [mm] |
32 |
| |
Height (packaging excluded) [mm] |
78 |
| Weight |
| |
(packaging excluded) [kg] |
0.25 |
|