Hotline: 0984.843.683 Email: info@ttech.vn  Zalo: 0984.843.683

Thiết bị hiệu chuẩn PAT Calibrator 5080 Time Electronics

Mã sản phẩm: 5080
Sử dụng cho Model:
Hãng SX: Time Electronics
Xuất xứ
Bảo hành
Tình trạng

Tình trạng: Còn hàng

Đặt hàng
Calibrate PAT Testers
Calibrate VDE0701 testers
Battery powered
LCD display of voltage & current
Safety interlock feature
Earth bond currents up to 50A AC
Load test currents up to 13A AC

Liên Hệ Hỗ Trợ

    • SĐT: 0984 843 683

    • Mail: info@ttech.vn

      • Zalo: 0984.843.683

Thông tin sản phẩm

A precision calibrator designed to provide rapid high accuracy calibration of portable appliance testers and insulation/continuity testers.
The 5080 PAT calibrator has functions for earth bond, insulation, leakage, touch leakage, and load test.  


Housed in a robust safety case the 5080 is easily portable and ideal for field calibration work. It is battery powered, which ensures isolation and prevents inaccuracies due to stray leakage. Features include safety interlock that prevents contact with earth bond studs during insulation and leakage tests, and an LCD display for voltage and current.


The 5080 is a dedicated solution for PAT testers and part of the electrical testing calibration range from Time Electronics. Other models include the 5030 electrical tester calibrator for RCD, loop, insulation, earth testers and multifunction installation testers. For insulation testers the 5069 InsCal is a portable instrument with resistance up to 100GOhm, and 10kV operation.


Values / Accuracy

20mΩ, accuracy 5%
190mΩ, 210mΩ, 950mΩ, 1.050mΩ, 1.08Ω, 2Ω, 10Ω, 18Ω, accuracy 1%

Open circuit voltage measurement

Range: 0 to 20V
Accuracy: 0.25% of full scale

High current AC measurement

Range: 0 to 50A AC
Accuracy: 0.5% of reading +/- 0.2A

Low current AC measurement

Range: 0 to 2A AC
Accuracy: 0.5% of reading +/- 2mA

Low current DC measurement

Range: 0 to 2A DC
Accuracy: 1% of reading +/- 2mA

Values / Accuracy

95kΩ, 105kΩ, 500kΩ, 950kΩ, 1.05MΩ, 5MΩ, 10MΩ, accuracy 0.1%
20MΩ, 50MΩ, 100MΩ, accuracy 1.0%

Open circuit voltage measurement

Range: 0 to 1kV DC
Accuracy: 0.25% of full scale

Current measurement Range: 0 to 20mA DC. Accuracy: 0.25% of full scale
Nominal Leakage Currents At 230V AC of 0.5, 1, 2, 5, 10, 15mA

Mains voltage measurement

Range: 0 to 500V AC
Accuracy 0.25% of full scale

Leakage current measurement

Range: 0 to 20mA AC
Accuracy 0.25% of full scale

Current 1.9mA AC 50 +/-5 Hz, into 2K2 maximum load resistance
Current measurement Range: 0 to 2mA AC. Accuracy: 0.25% of full scale

Mains voltage measurement

Range: 0 to 500V AC
Accuracy: 0.25% of full scale

Load current measurement

Range: 0 to 13A AC
Accuracy: 0.5% of full scale


Power Internal battery 6V re-chargeable NiCad, >200 hrs between charges.
Dimensions W406 x H175 x D330mm
Weight 5.5kg
Supplied With 4mm terminal box adaptor, 110V adaptor, IEC connector (for external load), battery charger, and user manual.
Optional Extras Calibration certificates traceable NPL and UKAS
Country of Origin UK