AC Hipot test
|
| Rated output capacity |
AN9638H(F) |
500VA(5000V/100mA),short circuit current >200mA |
| AN9637H(F) |
200VA(5000V/40mA),short circuit current >200mA |
| Output voltage setting |
Range,Accuracy |
100~5000V,±(2%×setting+5counts) |
| Output frequency setting |
Range,Accuracy |
50Hz or 60Hz,±0.1%×setting |
| Alarm current limits setting |
Upper-limit range,Accuracy |
0.10~100.00mA(or 40.00mA),±(2%×setting+5counts) |
| Lower-limit range,Accuracy |
0.000~9.999mA,±(2%×setting+5counts) |
| Time setting |
Range |
0.5~999.9s(0 is infinite) |
| Ramp up/down time range |
0.1~999.9s |
| Accuracy |
±(0.2%×setting+1count) |
| Measurement |
Voltage range,Accuracy |
0.01~5.00kV,±(1.5%×reading+1count) |
| Frequency range,Accuracy |
50Hz or 60Hz,±0.1%×reading |
| Current range,Accuracy |
0.10~100.00mA(or 40.00mA),±(2%×reading+2counts) |
| Time range,Accuracy |
0.1~999.9s,±(0.2%×reading+1count) |
| Output voltage waveform, distortion, regulation |
Sine wave,<2%(pure resistance load),<2%×setting+5V)(from empty load to full load) |
| Start voltage setting |
(0%~50%)×output voltage setting |
| Current compensation setting |
0.000~100.00mA(or 40.00mA),auto、manual |
| Arc detection |
1~9 level,9 level is optimally sensitive,0 is OFF |
DC Hipot test
|
| Output voltage setting |
Range,Accuracy |
100~6000VDC,±(2%×setting+5counts) |
| Alarm current limits setting |
Upper-limit,Accuracy |
0~10000μA,±(2%×setting+5counts) |
| lower-limit,Accuracy |
0.0~999.9μA,±(2%×setting+5counts) |
| Time setting |
Range |
0.5~999.9s(0 is infinite) |
| Ramp up time range |
0.1~999.9s |
| Ramp down time range |
0.3~999.9s(0 is OFF) |
| Accuracy |
±(0.2%×setting+1 count) |
| Measurement |
Voltage range,Accuracy |
0.01~6.00VDC,±(1.5%×reading+1count) |
| Frequency range,Accuracy |
0.0~10000uA,±(2%×reading+5count) |
| Current range,Accuracy |
0.1~999.9s,±(0.2%×reading+1count) |
| Rated output capacity |
60VA(6000VDC/10mA) |
| Output voltage ripple, regulation |
<5%(pure resistance load,6000V/10mA),<(2%×setting+5V)(from empty load to full load) |
| Compensation current Setting |
0 ~200.0μA,auto, manual |
| Start voltage setting |
(0%~50%)× setting output voltage |
| Charging current lower limit |
(0~3.500)μA,auto, manual |
| Discharge time |
≤200ms |
| Arc detection |
1~9 level,9 level is optimally sensitive,0 is OFF |