Thiết bị tạo xung điện tìm điểm lỗi cáp Tinsley 5915
The Tinsley Electroding Generator, type 5915, has been developed with British Telecom to locate Submarine Telephone Cables. The method employed is the well established electroding technique. The unit is self-contained, desk top mounting, enabling tests to be carried out without the power feed connected to the cable under test.
For more information about this product contact Tinsley
The 5915 Tinsley Electroding Generator is intended as an aid to cable repair ships in locating and identifying telephone cables. The Electroding Generator energises the Submarine Cable with a low frequency sine wave signal of up to 500mA at 500 Volts peak to peak. The Electroding Generator is located in the terminal station normally nearest to the fault area and connected to the cable under test by means of two safety probes built-in the instrument.
Principle of Operation
The Electroding Generator is a low frequency oscillator with a sine wave output capable of delivering up to 500mA at 500 Volts peak to peak at any frequency from 5Hz to 99.9Hz. The frequency is selected by digital thumbwheel switches, peak current is set via a front panel rotary control. The Current and Voltage levels are clearly displayed on Front Panel Precision Analogue Meters.
The current waveform is controlled to be sinusoidal. The test current has a DC bias to improve the sensitivity detection over longer distance. The test current can be applied in either the forward direction only or in the reverse or forward bias, as required. Longer cable can normally be electroded by energising in the reverse direction. A crystal controlled oscillator ensures that the frequency does not drift while testing is in progress.
Output connections are made by permanently connected probes, which are fully shrouded. A safety circuit disables the Generator output whilst the probes are being applied to the cable under test. A special compartment on the rear of the instrument is provided for stowing the output probes when not in use.
A frequency monitor point (square wave at signal frequency) is provided on the rear on the instrument. Output level is TTL compatible.