- Universal-measuring-transducers MU1000K can measure signals Pt100 (RTD) and DC current (0/4-20 mA) and voltage (DC 0/2-10 V). Several measuring-ranges are pre-programmed. More can be easily scaled. Temperatures at sensors Pt 100 can be evaluated from -200 °C to + 800 °.
- The output-signals 0/2-10 V and 0/4-20 mA are potentially separated from inputs and supply voltage. With its universal power-supply AC/DC 24-240 V the measuring transducer can be connected to all common supply-voltages.
- Current input 0-20mA, scalable
- Voltage input 0-10V, scalable
- Input Pt 100, 3-wire, -200…+800 °C, scalable
- Output signal 0-20mA and 0-10V or 4-20mA and 2-10V
- Rated Supply Voltage AC/DC 24-240V
- Insulation between inputs, outputs and supply voltage
- Standard ranges adjustable, universally scalable input ranges
Thông số kỹ thuật
- Rated supply voltage Us.......AC/DC 24 – 240 V 0/50/60 Hz < 3 W < 5 VA
- Tolerance.......DC 20,4 - 297 V ; AC 20 - 264 Vv
- Housing.......Type K
- Dimension (H x W x D).......75 x 22,5 x 110 mm
- Line connection solid wire.......each 1 x 0,5…2,5 mm2
- Stranded wire with insulated ferrules.......each 1 x 0,14…1,5 mm2
- Torque.......0.5 Nm (3,6 lb.in)
- Protection class housing.......IP 40
- Protection class terminals.......IP 20
- Mounting.......Snap mounting on 35 mm standard rail EN 60 715 or M4 screws
- Weight.......app. 100 g