Hotline: 0984.843.683 Email: info@ttech.vn  Zalo: 0984.843.683

Rack Mount Surge Eliminator with Remote SX1120RT SurgeX

Mã sản phẩm: SX1120RT
Sử dụng cho Model:
Hãng SX: SurgeX
Xuất xứ
Bảo hành
Tình trạng

Tình trạng: Còn hàng

Đặt hàng
The SurgeX SX1120RT rack mount surge eliminator with remote provides professional-grade surge elimination and power conditioning for audio, video, and security rack mount equipment. Our top-of-the-line protection is the ultimate solution to safeguard audio video systems that rely on mission critical equipment for optimal performance.

Liên Hệ Hỗ Trợ

    • SĐT: 0984 843 683

    • Mail: info@ttech.vn

      • Zalo: 0984.843.683

Thông tin sản phẩm

Features

SX1120RT Rack Mount Surge Eliminator with Remote, 120V/20A, 1U
Eliminates surge energy up to 6,000 Volts/3,000 Amps
Protects audio video based equipment from power disturbances and catastrophic damage
Provides 100% fail-safe, non-sacrificial protection
Features SurgeX Advanced Series Mode® surge elimination technology, EMI/RFI, CouVS
Catastrophic over/under Voltage Shutdown Protection, ICE Inrush Current Elimination, and thermal circuit breaker overload protection
Improves audio and video performance
A-1-1 Certified


Model: SX1120RT Specifications
Load Rating 15 Amps @ 120 volts
Power Requirements (no load) 15 watts
Surge Let-Through Voltage (6000-volt surge) 0 volts
UL 1449 Adjunct Classification Test Results 1000 surges, 6000 volts, 3000 amps, B3 pulse
Measured suppressed voltage 170 volts, no failures
Federal Guidelines Grade A, Class 1, Mode 1 (CID A-A-55818)
EMI/RFI Filter, Normal Mode (50-ohm load) 40 dB @ 100 kHz; 50 dB @ 300 kHz; 50 dB @ 3 MHz; 50 dB @ 30 MHz
EMI/RFI Filter, Common Mode (50-ohm load) 18 dB @ 300 kHz; 30 dB @ 1 MHz; 50 dB @ 5 MHz; 50 dB @ 20 MHz
Maximum Applied Surge Voltage 6000 volts*
Maximum Applied Surge Current Unlimited, due to current limiting*
Maximum Applied Surge Energy Unlimited, due to current limiting*
Endurance (C62.41-1991 Category B3 pulses) 1 kV>500,000; 3 kV>10,000; 6 kV>1000
Undervoltage Shutdown 90 volts (resume at 100 v)
Overvoltage Shutdown 145 volts (resume at 135 v)
Maximum Load Inrush Current During Power-up 1000 Joules
Remote Turn-on Applied Voltage Range 5 to 30 volts DC
Contact Closure 1.5 mA
5 V DC Applied Voltage 0.1 mA
12 V DC Applied Voltage 1.5 mA
24 V DC Applied Voltage 5.0 mA
Auxiliary Relay Contact Rating 30 Volts at 1 Amp
LED Output 12 volts DC, maximum 20 mA (resistor required)
Dimensions 1.75" H x 19" W x 10.5" D (4.5 x 48.3 x 26.7 cm)
Weight 11 lbs (5 kg)
Temperature Range 5º to 35º C
Humidity Range 5% to 95% R.H., non-condensing
Agency Listings ETL and cETL certified to (UL 1449; CSA C22.2 No.8-M1986, R2000)