Hotline: 0984.843.683 Email: info@ttech.vn  Zalo: 0984.843.683

Thiết bị đo điện trở cách điện MD-10KVx Tentech

Mã sản phẩm: MD-10KVx
Sử dụng cho Model:
Hãng SX: Tentech
Xuất xứ
Bảo hành
Tình trạng

Tình trạng: Còn hàng

Đặt hàng
The digital insulation tester model MD-10KVx is Tamat's cutting edge insulation analyzer equipment and it is one of the most complete and sophisticated available in the international market.
A powerful software allows for further analysis of tests results, including features such as graphical representation and automatic report generation. Its proven technology provides safe, reliable and accurate measurements of insulation resistances up to 10TΩ, with 4 pre-selected test voltages, 500V - 1kV - 5kV - 10kV. Other test voltages may be selected in steps of 25V, 100V or 500V.

Liên Hệ Hỗ Trợ

    • SĐT: 0984 843 683

    • Mail: info@ttech.vn

      • Zalo: 0984.843.683

Thông tin sản phẩm

10 kV Digital Insulation Tester

• Insulation resistances up to 10 TΩ
• Automated tests:
- Absorption index
- Polarization index
- Capacitance
- Leakage current
- AC/DC voltmeter
• Step voltage test
• Real time clock and calendar
• Built-in printer
• 4000 readings memory
• Software for data management


Test voltage
500 V, 1000 V, 5000 V, 10000 V directly, one button selectable. 500 V to 10 kV in 25 V, 100 V or 500 V steps. DC, negative.

Maximum resistance reading 
10 TΩ @ 10 kV. 

DC voltmeter 
15 V up to 600 Vcc.
Accuracy: ±(5% of reading + 3 digits). 

AC voltmeter 
15 V up to 600 V r.m.s.
Accuracy: ±(5% of reading + 3 digits). 

Overvoltage category
CAT. III - 600 V. 

Leakage current measurement 
1 nA up to 1500 µA ±(10% of reading + 3 digits). 

Capacitance measurement 
50 nF up to 10 µF @ 500 V.
50 nF up to 5 µF @ 1,000 V.
30 nF up to 2 µF @ 2,500 V.
30 nF up to 1 µF @ 5,000 V.
30 nF up to 680 nF @ 10,000 V.
Accuracy: ±10% of reading ± 3 digits.

Short circuit 
Max. 2 mA. 

Display 
Digital and bargraph reading. 

Test voltages accuracy 
± 3% of nominal test voltages on 10 GΩ. 

Insulation tester basic accuracy 
± 5% of reading from 1 MΩ to 1 TΩ @ 10 kV.
± 20% of reading from 1 TΩ to 10 TΩ @ 10 kV.
(for lower test voltages, the upper limit will be reduced proportionally)
± 20% of reading ± 5 digitos from 10 kΩ to 100 kΩ.
± 10% of reading ± 5 digitos from 100 kΩ to 1 MΩ. 

Advanced Features 
Automated Polarization Index calculation.
Automated Dielectric Absorption Ratio calculation.
Programmable Pass-Fail test.
Step Voltage Test.
4000 readings memory.
Switchable filter to remove external noise interference. 

Built-in printer 
Prints elapsed time, actual voltage and resistance measured each 15 seconds. 