Discover the perfect combination of features and power in this compact, lightweight pump that gets the job done. The AirChek® XR5000 personal air sampling pump with Li-Ion battery provides powerful flows for particulate sampling, low flows for gas and vapor sampling, and the long run-times for low-concentration sampling. 

Liên Hệ Hỗ Trợ

    • SĐT: 0984 843 683

    • Mail: info@ttech.vn

      • Zalo: 0984.843.683

Thông tin sản phẩm

Flow Range
1000 to 5000 ml/min  (5 to 500 ml/min requires optional low flow kit)
Compensation Range
5000 ml/min at 10 inches water back pressure
4000 ml/min at 20 inches water back pressure
2000 ml/min at 50 inches water back pressure
Typical Back Pressure of Sampling Media (inches water)
Flow Rate (L/min)
1.0
1.5
2.0
2.5
3.0
3.5
4.0
5.0
Filter/Pore Size (µm)                
25-mm MCE/0.8
6
9
12
15
18
21
25
31
25-mm MCE/0.45
14
22
28
35
40
44
50
63
37-mm MCE/0.8
2
3
4
5
6
7
9
11
37-mm PVC/5.0
1
1
2
2
2.5
3
3
4
37-mm polycarbonate/0.45
4
6
8
10
12
15
17
21
25-mm MCE/0.45 microvacuum
21
31
40
48
59
69
79
100
37-mm PTFE/1.0
1.5
2.5
4
5.5
7
8
9.5
12
Compare the information in this table to pump compensation range to determine appropriate applications.
Flow Compensation System
Patented isothermal closed loop flow sensor
(U.S. Patent No. 5,892,160)
Tubing
Requires 1/4-inch ID tubing
Accuracies
Timing: 1 min/mo at 25 C 
Flow Rate: ± 5% of set-point after calibration to desired flow
Battery Charge Level Indicator
Icon displays on LCD at full, mid, low charge, imminent low battery fault, and low battery fault.
Temperature Range
Operating: 32 to 104 F (0 to 40 C) 
Charging: 32 to 113 F (0 to 45 C) 
Storage: -4 to 95 F (-20 to 35 C)
Typical Run Times
XR5000 Model
2 L/min
5 L/min
High-power Li-Ion
40 hrs
22 hrs
Standard Li-Ion
20 hrs
11 hrs
Timer Display Range
1 to 9999 minutes (6.8 days). If run time exceeds 6.8 days, timer display rolls over.
Flow Fault
If pump is unable to compensate for > 15 seconds due to excessive back pressure, the pump stops and holds run time display. Auto-restart is attempted every 15 seconds up to 5 times.
Low Battery Fault
15 sec to sleep
Auto-off
5 min of inactivity
Battery Pack
(model dependent)
High-power Li-Ion (4 cell), rechargeable, 7.4 V, 4.4 Ah, 32.6 Wh capacity
or 
Standard Li-Ion (2 cell), rechargeable, 7.4 V, 2.2 Ah, 16.3 Wh capacity
Battery Recharge Time
(with SKC-approved charger)
Standard Li-Ion (2 cell): approximately 4 hrs
High-power Li-Ion (4 cell): approximately 8 hrs
Size
High-power Li-Ion model: 5.5 x 3 x 2.3 in (14 x 7.6 x 5.8 cm) 
Standard Li-Ion model: 4.3 x 3 x 2.3 in (10.9 x 7.6 x 5.8 cm)
Weight
High-power Li-Ion model: 21 oz (0.6 kg) 
Standard Li-Ion model: 16 oz (0.45 kg)
Case
Anti-static plastic
RFI/EMI Shielding
CE marked for RFI/EMI protection
Approvals

 for use in hazardous locations. Models that are UL Listed for intrinsic safety contain the  logo on the label. These models must be used with battery pack Cat. No. P85004 or P85002 to maintain the UL intrinsic safety listing.