Relative humidity |
Measurement range |
0 ... 100 % RH |
Accuracy (including non-linearity, hysteresis, and repeatability) |
with Vaisala HUMICAP® 180 or 180R |
for typical applications |
with Vaisala HUMICAP® 180C or 180RC |
for applications with chemical purge/warmed probe |
at +15 ... +25 °C (59 ... +77 °F) |
±1 %RH (0 ... 90 %)
±1.7 %RH (90 ... 100 %RH) |
at -20 ... +40 °C (-4 ... +104 °F) |
±(1.0 + 0.008 x reading) %RH |
at -40 ... +180 °C (-40 ... +356 °F) |
±(1.5 + 0.015 x reading) %RH |
Factory calibration uncertainty (+20 °C) |
± 0.6 % RH (0 ... 40 %RH)
± 1.0 % RH (40 ... 97 %RH) |
Response time (90 %) at +20 °C (+68 °F) |
8 s / 17 s* with grid filter |
in still air |
20 s / 50 s* with grid + steel netting filter
40 s / 60 s* with sintered filter |
Temperature |
Accuracy at +20 °C (+68 °F) |
± 0.2 °C (± 0.36 °F) |
Inputs and outputs |
Operating voltage |
10 ... 35 VDC, 24 VAC |
with optional power supply module |
100 ... 240 VAC, 50/60 HZ |
Power consumption at +20 °C (Uin 24 VDC) |
RS-232 |
max. 25 mA |
Uout 2 x 0 ... 1 V/0 ... 5 V/0 ... 10 |
max. 25 mA |
Iout 2 x 0 ... 20 mA |
max. 60 mA |
display and backlight |
+ 20 mA |
during chemical purge |
max. 110 mA |
during probe heating (HMT337) |
+ 120 mA |
Analog outputs (2 standard, 3rd optional) |
current output |
0 ... 20 mA, 4 ... 20 mA |
voltage output |
0... 1 V, 0... 5 V, 0... 10 V |
Accuracy of analog outputs at +20 °C |
±0.05% full scale |
Temperature dependence of the
analog outputs |
±0.005%/°C full scale |
External loads |
current outputs |
RL < 500 ohm |
0 ... 1 V output |
RL > 2 kohm |
0 ... 5 V and 0 ... 10 V outputs |
RL > 10 kohm |
Max. wire size |
0.5 mm2 (AWG 20) stranded wires recommended |
Digital outputs |
RS-232, RS-485 (optional) |
Service connection |
RS-232, USB |
Relay outputs (optional) |
0.5 A, 250 VAC |
Ethernet interface (optional) |
Supported standards |
10/100Base-T |
Connector |
RJ45 |
Protocols |
Telnet |
Software support |
Vaisala MI70 link |
Ethernet interface (optional) |
Supported standards |
802.11b |
Connector Type |
RP-SMA |
Protocols |
Telnet |
Security |
WEP 64/128,WPA |
Software support |
Vaisala MI70 link |
Authentication / Encryption (WLAN) |
Open / no encryption
Open / WEP
WPA Pre shared key / TKIP
WPA Pre shared key / CCMP (a.k.a. WPA2) |
Optional data logger with real-time clock |
Logged parameters |
max. three with trend/min/max values |
Logging interval |
10 sec (fixed) |
Max. logging period |
4 years 5 months |
Logged points |
13.7 million points per parameter |
Battery lifetime |
min. 5 years |
Display |
LCD with backlight, graphic trend display of any parameter |
Menu languages |
English, Chinese, Japanese, Spanish, German, French, Swedish, Russian, Finnish |