Type test |
Indicator SED-30 |
SEU11 |
VUS11 |
VUS11-R |
Analog Output |
1~5 VDC +/- 0.1V |
1~5 VDC +/- 0.1V |
1~5 VDC +/- 0.1V |
1~5 VDC +/- 0.1V |
Analog Output Current |
1 mA max. |
1 mA max. |
1 mA max. |
1 mA max. |
Display Units |
kPa, kgf/cm2, gf/cm2, mmHg, mmH20, bar, mbar, psi, kpsi, MPa, in.Hg |
|
|
|
Fluid Admitted |
|
Air, Inert Gas |
Air, Inert Gas |
Air, Inert Gas |
Hysteresis (Switch Output) |
Fixed to 1% of F.S. |
Fixed to 2% of F.S. |
Fixed to 2% of F.S. |
Fixed to 2% of F.S. |
Linearity |
+/- 0.5% of full span |
+/- 0.5% of full span |
+/- 0.5% of full span |
+/- 0.5% of full span |
Operating Accuracy |
+/- 1% of full span |
+/- 3% of full span |
+/- 3% of full span |
+/- 3% of full span |
Operating Humidity Range |
35~85%RH |
35~85%RH |
35~85%RH |
35~85%RH |
Output Type |
2 switches |
1 switch or 1 analog |
1 switch or 1 analog |
1 switch or 1 analog |
Power Consumption |
50 mA max. |
20 mA or less |
20 mA or less |
20 mA or less |
Power Supply |
10.8~30VDC |
10.8~30VDC |
10.8~30VDC |
10.8~30VDC |
Pressure Setting Range |
|
0~150 psi (0~1MPa) |
0~-30 in.Hg (0~-100 kPa) |
-30~89in.Hg (-100~300 kPa) |
Proof Pressure |
|
218 psi (1.5MPa) |
29 psi (200 kPa) |
87 psi (600 kPa) |
Protective Structure |
IEC IP40 |
IEC IP40 |
IEC IP40 |
IEC IP40 |
Service Pressure Range at 20ºC |
|
0~150 psi (0~1MPa) |
0~-30 in.Hg (0~-100 kPa) |
-30~89in.Hg (-100~300 kPa) |
Service Temperature Range |
32~122ºF (0~50ºC) |
32~140ºF (0~60ºC) |
32~140ºF (0~60ºC) |
32~140ºF (0~60ºC) |
Switch Output Type |
30V 100mA NPN |
30V 80mA NPN |
30V 80mA NPN |
30V 80mA NPN |
|