Cap-Level® II & Cap-Level® IIA are designed for level monitoring and control. The 4-20mA output provides a selectable dampening function to stabilize readings where severe agitation is present. Simple zero and span adjustment make calibration easy. The relay logic circuitry offers the flexibility to control multiple pumps, conveyors and alarms. Each relay can be set to turn your equipment on and off at any selected point on the probe - without any external latching devices. Failsafe selection gives the security of fault indication and/or conveyor stop if power is lost. The probe configurations and materials offered allow you to custom fit Cap-Level® II to your application. Designs such as the type “E” and type “H” tie-down, allow use in tall silos and include a unique cable adjustments.
Operating Power: Cap Level II: 120 VAC, 240 VAC; Cap Level IIA: 15-32 VDC
Power Consumption: 8 Watts
Operating Temperature: -40º to 160º F (-40º to 71º C) Hysteresis: 2.5% of span min, 100% max
Analog Output: 4-20mA into 400 Ohms max
Relay Output: SPDT, 3 amps @ 120 VAC
Accuracy: 1% FS with Constant Dielectric
Analog: course and fine zero/span, non-interacting relays: hi, low setpoints and hysteresis set as % of span