- Vacuum equipment
- Visual Montoring of air and gas pressure for compressors
- Heating, ventilation, climate
- Pumps and regulators
- Non-corrosive gas, air, oil and water
- Pneumatics
- Medical gas cylinders
- Media not attack to brass
Steady : 3/4 of full scale value(recommendation : 25% to 75%
of full scale)
Fluctuating : 2/3 of full scale value(recommendation : lower
50% of full scale)
Short time : full scale value
Reference Accuracy
40mm : ± 3.0% of Full Scale
50mm, 60mm & 75mm : ± 1.5% of Full Scale
100mm, 150mm & 200mm : ± 1.5% of Full Scale
Scale Ranges *
40mm : 0 ~ 0.2 to 0 ~ 35 MPa
50mm : Vacuum & 0 ~ 0.2 to 0 ~ 35 MPa
60mm & 75mm : Vacuum, Compound & 0 ~ 0.1 to 0 ~ 35 MPa
100mm & 150mm : Vacuum, Compound & 0 ~ 0.1 to 0 ~ 100 MPa
200mm : 0 ~ 0.2 to 0 ~ 15 MPa
* For more information, see the ordering information table.
Standard Pressure Connection
40mm : PT("R" in ISO) 1/8"
50mm & 60mm : PT("R" in ISO) 1/4"
75mm & 100mm : PT("R" in ISO) 3/8"
150mm & 200mm : PT("R" in ISO) 3/8"
* Throttling screw inserted in the pressure port.
Material
Case : Black Finished Steel
Ring(Cover) : Black Finished Steel
Window * : Glass
Pointer : Aluminum Black Finished
Connection : Brass
Element : Phosphor Bronze
Movement : Phosphor Bronze
Dial Plate : White Aluminum with Black Graduations