- High precision gauges
- Instrument shops, Laboratories
- Precise applications requiring high accuracy
- Where the operating error must be minimized
Working Pressure
Steady : 3/4 of full scale value(recommendation : 25% to 75% of full scale)
Fluctuating : 2/3 of full scale value(recommendation : lower 50% of full scale)
Short time : 130% of full scale value(over range protection)
Scale Ranges *
Vacuum Compound & 0 ~ 0.6, 0 ~ 1000 bar
* For more information, see the ordering information table.
Pressure Connection
PF("G" in ISO) 3/8", PT("R" in ISO) 1/2"
Material
Case : 304 SS
Ring(Cover) : 304 SS
Window : Glass(Standard) or Laminated Safety Glass(Option)
Pointer : Aluminum Alloy, Black Finished
Connection : 316 SS
Element(Bourdon Tube) : 316 SS
Movement : 304 SS
Dial : White Aluminum with Black & Red Graduations