Features
Pressure indicator, with upper and lower pressure signal setting function.
Contact signal of 100 VAC, 0.5A for alarm buzzer and lamp indication.
Pressure pointer provided with contact, ensuring accurate pressure indication and pressure setting.
Three contact types are available: upper, lower and upper/lower. The contact type can be modified on request.
Specifications
Profile |
ø75
AU type |
ø75
BU type |
ø75
DU type |
ø100
AU type |
ø100
BU type |
ø100
DU type |
Contact capacity |
AC100V 0.5A |
Accuracy |
Indication |
±1.6%/F.S or less |
Setting |
±2.0%/F.S or less |
Reproducibility |
±1.0%/F.S or less |
Cut-off difference |
±2.0%/F.S or less |
Weight |
380g |
420g |
320g |
670g |
730g |
710g |
Pressure Range Table
1 |
0~1.0MPa |
2.5 |
0~2.5MPa |
4 |
0~4MPa |
6 |
0~6MPa |
10 |
0~10MPa |
16 |
0~16MPa |
25 |
0~25MPa |
40 |
0~40MPa |
|