- Flow metering of liquids and gases in pipelines.
- Indication of momentary volume- or mass flow per time unit.
- Applications: chemical-, petrochemical-,oil- and gas industry
- Especially suitable for its robust design for processes under difficult and harsh conditions
- Body:
+ Materials: 1.4404 (316 L) / 1.4571 (316 Ti), Hastelloy C-22, Monel, PTFE, (others on request)
+ End connections: flanges acc. EN 1092, ASME B16.5, DIN2512,JIS, NPT, pipe joint, special connections
+ Nominal pressure: PN 40, ASME Cl150 / 300 higher pressure rate up to 600 bar optional
+ Process temperature: -40°C bis +350°C
+ Ambient temperature: -40°C bis +80°C
+ Ingress protection: IP 65 / IP 67 (EN60529)
+ CE-mark: Pressure Equipment Directive 97/23/EG
+ Ranges: from 0,5-5 l/h up to 13.000-6130.000l/h water
+ Display: Aluminum (enamel finish) or stainless steel
+ outputs: inductive switch
+ inductive switch (safety function))
+ micro switch (others on request)
+ Ambient temperature: -40°C up to +80°C (without switch)); -40°C up to +65°C (with switch)
- Transmitter ES:
+ Power supply: 14 - 30 VDC
+ Outputs: passive, galvanically isolated
+ Analog: 4-20 mA
+ Binary 1 and 2: Ui=30 V, Ii=20mA, Pi=100 mW
+ Input binary: Counter reset (only for ES with counter module)
+ Ambient temperature: -40°C up to +70°C
- Ingress protection: IP 20 (EN60529
- Accuracy:
+ Liquid: ± 1,6% of upper range value (BGN-S/H)
+ ± 0,2% with transmitter (ES)
+ Gas: ± 1,8% of upper range value (BGN-S/H)
+ ± 0,2% with transmitter (ES)