- Ranges:
+ Water 20 °C, min: 0,02-0,25 l/h, max:10-100 l/h
+ Air 20 °C, 1,2 bar abs., min: 2-20 Nl/h, max:300-3000 Nl/h
- Electronic output: (Option)
+ 1 inductive switch, mono- or bistable
+ Mono-stable RC 10/15-14-N0
+ Bi- stable RC 10/15-14-N3
+ Make: Pepperl+Fuchs,
- Accuracy:
+ Reference conditions: water 20 °C (air 20 °C, 1,2 bar abs)
+ Measuring error: ± 3 % qG= 50% acc. VDE/VDI 3513 Bl. 2
+ Repeatability : ± 1,0 % of upper range value
- Applications:
+ Metering of liquid products with suitable viscosity, free of solids, not clog and do not tend to form deposits..
+ Gases with linear flow characteristics and adequate inlet pressure.
- Ambient conditions:
+ Ambient temperature -20°C up to +100°C (risk of frost fracture!)(with switch +70°C)
+ Ingress protection: IP 65 (EN60529)
- Product conditions
+ without switch: -20°C up to +100°C
+ with switch: -20°C up to +70°C
- Ingress protection: IP 65 (EN60529)