- Ranges:
+ Water: 20 °C, min: 6,5-65 l/h, max:1.000-10.000l/h
+ Air: 0 °C, 1,013 bar abs., min: 150-1.500 Nl/h, max:18.000-180.000 Nl/h
- Display: Flow rate units on the glass cone.
- Accuracy class: (acc. VDE/VDI 3513, page 2):
+ Liquid: 1,6%
+ Gas: 2,5%
- Applications:
+ Metering of liquid products with suitable viscosity, free of solids, not clog and do not tend to form deposits.
+ Gases with linear flow characteristics and adequate inlet pressure
- Ambient conditions: Ambient temperature: -20°C up to +80°C
- Fluid conditions: Nominal pressure: 15 bar max. (depends on temperature and material, details see relevant data sheet)