Imaging And Optical Data
IR Resolution |
384 x 288 pixels, Focal Plane Array (FPA), Uncooled Microbalomenter |
Field of View (FOV) |
47.1° x 36.2° |
Minimum focus Distance |
0.3m (0.99ft.) |
Spatial Resolution |
(IFOV) 2.28 mrad |
Thermal Sensitivity / NETD |
< 0.06°C @ +30°C (+86°F) / 60 mK |
Image Frequency |
50Hz |
Focus mode |
Manual |
Zoom |
32x Continuous, Digital Zoom |
Rotate |
0°- 360°, Continuous Change by 1° |
Image Presentation
Display |
3.5” TFT, Capacitive Touch Screen |
Image modes |
IR Image, Visual Image, Picture in Picture |
Picture in Picture |
IR Area on Visual Image or Visual Image Area on IR |
Color Palettes |
GRAY/ GRAYIRON / RAINBOW / FEATHER |
Measurement
Object Temperature Range |
Low Range -20°C to + 150°C (-4°F to + 302°F) |
High Range 0°C to + 400°C (+32°F to + 752°F) |
Accuracy |
±2°C (±3.6°F) or ±2% of Reading |
Measurement Analysis
Spotmeter |
3 |
Emissivity Adjustable |
0.01 ~ 1.0 Adjustable |
Emissivity Table |
Emissivity Table of Predefned Materials |
Line |
2 lines (Horizontal and Vertical) |
Area |
3 Boxes with max. / min. / Average |
Automatic Hot / Cold Detection |
Auto Hot or Cold Spotmeter Markers |
Isotherm |
Detect High / Low Temperature / Interval |
Difference Temperature |
Delta Temperature Between Measurement Pointer and Reference Pointer |
Measurement corrections |
Emissivity, Ambient Temperature, Distance, Relative Humidity, Offset Temperature |
|