Output current limiting can be set with positive and negative peak values and effective value.
After the activation of the limiter, the output can be automatically restored or turned off after a set time.
This function is effective for limiting the rush current of motors,large- capacity capacitors, etc. and protecting against abnormal current caused when prototype operations fail.
With AC 3 kVA, full-power 3kW output is also available for DC. The capacity is not reduced in DC mode. Since the AC+DC mode is also available, this power source can be used for a variety of applications.
A high S/N ratio is achieved in each mode. Use of the current limiter function in DC mode enables the high performance use of the unit as a DC power source. In addition, in AC+DC mode, simulations can be performed in which the DC component is generated temporarily, such as a sudden change in voltage.
Thông số kỹ thuật